Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALNOR, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALNOR, INC. in 1737 ALAFAYA TRAIL, ORLANDO, FL 32826 (NAICS 811111). OSHA activity number 339948713.

Watch Alnor, INC. — free Get an email when a new federal OSHA severe-injury report for Alnor, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ALNOR, INC.
Site address
1737 ALAFAYA TRAIL
City
ORLANDO
State
FL
ZIP
32826
Mailing
3901 NW 29TH AVE, MIAMI, FL 33142
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
7
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 22 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and/or crushing hazards while repairing/servicing vehicles from underneath defective and modified pneumatic/hydraulic automotive lifts:  (a) at the shop - employees worked under automotive lifts with defects including, but not limited to, inoperative/non-existent safety lock mechanisms, uncontrolled movement, uneven and/or rough up/down operation, and fluid leaks that were not periodically inspected; observed on or about 9/10/14.  (b) at the shop - employees worked under automotive lifts with defects including, but not limited to, inoperative/non-existent safety lock mechanisms, uncontrolled movement, uneven and/or rough up/down operation, and fluid leaks for which there was not a planned maintenance program; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.23 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  (a) in the shop - the railing on the second floor was missing a mid-rail; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  (a) in the shop - there was not a work rest on the abrasive wheel side of the bench grinder (Craftsman serial #9210100) used to smooth muffler exhausts and sharpen parts and bits; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) in the shop - there was not an adjustable tongue guard on the abrasive wheel side of the bench grinder (Craftsman serial #9210100) used to smooth muffler exhausts and sharpen parts and bits; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.243 B02

Serious Gravity 5 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected.  (a) in the shop - worm-drive hose clamps not designed for use with air hoses supplying compressed air at 175 psi were used to attach air hoses to hose fittings, exposing employees to a struck-by hazard of the whipping action of the hose or the clamp; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) northeast corner of shop - an oxygen cylinder was stored next to an acetylene cylinder, exposing employees to a fire/explosion hazard; observed on or about 9/10/14.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) center post toward rear of shop - the Amerex portable fire extinguisher received the last maintenance check in June 2010; observed on or about 9/10/14.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339948713.