Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PORT BLUE LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PORT BLUE LLC in 301 6TH STREET, RACINE, WI 53403 (NAICS 238910). OSHA activity number 339950651.

Watch Port Blue LLC — free Get an email when a new federal OSHA severe-injury report for Port Blue LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PORT BLUE LLC
Site address
301 6TH STREET
City
RACINE
State
WI
ZIP
53403
Mailing
P.O. BOX 1364, RACINE, WI 53403
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
8
Ownership type
A

10 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103)    (a) On or about 9/12/2014, a written respiratory protection program was not established and implemented for employees performing interior demolition of the site.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)  (a) On or about 9/12/2014, a medical evaluation of the employee's ability to use a respirator was not obtained prior to providing elastomeric respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103)  (a) On or about 9/12/2014, demolition laborers who used elastomeric full face or half face cartridge respirators were not provided a fit test to ensure proper respirator selection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (Construction Reference 1926.103)  (a) On or about 9/12/2014 employees provided with elastomeric cartridge respirators were not properly storing them to protect them from contamination and damage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II I

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.    (a)  On or about 9/12/2014 electrical cables for temporary lighting was hung through a door way without protection from damage, exposing employees to possible electric shock and fire hazards.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.405 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:  (a) On or about 9/12/2014, a temporary electrical circuit breaker box had open holes on the panel exposing employees to possible shock or fire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.850 I

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.850(i): Floor openings, not used as material drops, were not securely covered:    (a) On or about 9/12/2014, employees were exposed to holes on the first and second floors in the wood floor posing a trip hazard.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1101 K02 I

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced

Hazardous substances 9020

29 CFR 1926.1101(k)(2)(i): Before work subject to this standard began, the building and/or facility owner(s) did not determine the presence, location and quantity of asbestos containing material (ACM) and/or presumed asbestos containing material (PACM) at the worksite pursuant to 29 CFR 1926.1101(k)(1):    a)  On or about 9/12/2014 prior to the start of demolition activities a survey to determine the presence, location and quantity of asbestos containing materials was not performed.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1101 L04 II

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9020

29 CFR 1926.1101(l)(4)(ii): Asbestos containing waste and debris shall be promptly cleaned up and disposed of in leak tight containers.  a) On or about 9/5/2014, Thermal System Insulation containing asbestos that was discarded as waste and debris was not promptly cleaned and disposed of in leak tight containers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.850 A

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:  (a) On or about 9/12/2014, a written demolition building survey or plan was not developed and available.