RACINE, WI —
OSHA Inspection: PORT BLUE LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of PORT BLUE LLC in 301 6TH STREET, RACINE, WI 53403 (NAICS 238910). OSHA activity number 339950651.
Where did this inspection happen?
- Establishment
- PORT BLUE LLC
- Site address
- 301 6TH STREET
- City
- RACINE
- State
- WI
- ZIP
- 53403
- Mailing
- P.O. BOX 1364, RACINE, WI 53403
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 8
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) (a) On or about 9/12/2014, a written respiratory protection program was not established and implemented for employees performing interior demolition of the site.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) (a) On or about 9/12/2014, a medical evaluation of the employee's ability to use a respirator was not obtained prior to providing elastomeric respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103) (a) On or about 9/12/2014, demolition laborers who used elastomeric full face or half face cartridge respirators were not provided a fit test to ensure proper respirator selection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (Construction Reference 1926.103) (a) On or about 9/12/2014 employees provided with elastomeric cartridge respirators were not properly storing them to protect them from contamination and damage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 A02 II I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. (a) On or about 9/12/2014 electrical cables for temporary lighting was hung through a door way without protection from damage, exposing employees to possible electric shock and fire hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.405 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: (a) On or about 9/12/2014, a temporary electrical circuit breaker box had open holes on the panel exposing employees to possible shock or fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.850 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.850(i): Floor openings, not used as material drops, were not securely covered: (a) On or about 9/12/2014, employees were exposed to holes on the first and second floors in the wood floor posing a trip hazard.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1101 K02 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(k)(2)(i): Before work subject to this standard began, the building and/or facility owner(s) did not determine the presence, location and quantity of asbestos containing material (ACM) and/or presumed asbestos containing material (PACM) at the worksite pursuant to 29 CFR 1926.1101(k)(1): a) On or about 9/12/2014 prior to the start of demolition activities a survey to determine the presence, location and quantity of asbestos containing materials was not performed.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1101 L04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9020
General-duty citation text
29 CFR 1926.1101(l)(4)(ii): Asbestos containing waste and debris shall be promptly cleaned up and disposed of in leak tight containers. a) On or about 9/5/2014, Thermal System Insulation containing asbestos that was discarded as waste and debris was not promptly cleaned and disposed of in leak tight containers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.850 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations: (a) On or about 9/12/2014, a written demolition building survey or plan was not developed and available.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339950651.