SCRANTON, PA —
OSHA Inspection: SHERIDAN MASONRY & CONCRETE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SHERIDAN MASONRY & CONCRETE in 601 WYOMING AVENUE, SCRANTON, PA 18509 (NAICS 238110). OSHA activity number 339959918.
Where did this inspection happen?
- Establishment
- SHERIDAN MASONRY & CONCRETE
- Site address
- 601 WYOMING AVENUE
- City
- SCRANTON
- State
- PA
- ZIP
- 18509
- Mailing
- 16040 AIRPORT DRIVE, DALTON, PA 18414
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) DG Nicholas Auto Parts Bldg: Employees were not protected from falling approximately 31 feet to the ground level by the use of personal fall arrest systems or guardrail systems while performing masonry restoration services from a tubular welded frame scaffold, observed on or about 9/19/2014. Abatement Certification Required.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) DG Nicholas Auto Parts Bldg: The 6th working level of a tubular welded frame scaffold was not fully planked or decked while employees were performing masonry restoration activities. The platform was 2 planks wide, observed on or about 9/19/2014. Abatement Certification Required
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E05 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: a) DG Nicholas Auto Parts: Employees were performing masonry restoration activities from a walkway on a tubular welded frame scaffold approximately 31 feet above the ground level with no guardrail system, observed on or about September 19, 2014. CORRECTED DURING INSPECTION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) DG Nicholas Auto Parts: The employer did not provide scaffold safety training for employees performing masonry restoration services from a tubular welded frame scaffold, on or about 9/19/2014. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C01 II
- Issued
- Penalty
- Initial $1700.00 · Current $850.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide: a) DG Nicholas Auto Parts: Three employees were sawing off concrete coping from a building that was 31 feet high. They were using a 35-foot high supported tubular welded frame spring lock scaffold which was not tied off to a sturdy structure to prevent from tipping or dislocation. Employees were exposed to fall hazards on or about September 19, 2014. CORRECTED DURING INSPECTION.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
More inspections in this industry (NAICS 238110)
FREELAND, WA—2026-07-10
WA317992031 - NORTH RIVER CONCRETE PUMPING LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
WEBSTER, TX—2026-07-09
ZITRO CONCRETE CONSTRUCTION LLC
CHICAGO, IL—2026-07-09
GOEBEL FORMING, LLC
SAN ANTONIO, TX—2026-07-08
URBAN CONCRETE CONTRACTORS LTD
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339959918.