Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHERIDAN MASONRY & CONCRETE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SHERIDAN MASONRY & CONCRETE in 601 WYOMING AVENUE, SCRANTON, PA 18509 (NAICS 238110). OSHA activity number 339959918.

Watch Sheridan Masonry & Concrete — free Get an email when a new federal OSHA severe-injury report for Sheridan Masonry & Concrete is published. One employer, no account, unsubscribe in one click.
Site address
601 WYOMING AVENUE
City
SCRANTON
State
PA
ZIP
18509
Mailing
16040 AIRPORT DRIVE, DALTON, PA 18414
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) DG Nicholas Auto Parts Bldg:  Employees were not protected from falling approximately 31 feet to the ground level by the use of personal fall arrest systems or guardrail systems while performing masonry restoration services from a tubular welded frame scaffold, observed on or about 9/19/2014.    Abatement Certification Required.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a) DG Nicholas Auto Parts Bldg:  The 6th working level of a tubular welded frame scaffold was not fully planked or decked while employees were performing masonry restoration activities. The platform was 2 planks wide, observed on or about 9/19/2014.    Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection:  a) DG Nicholas Auto Parts: Employees were performing masonry restoration activities from a walkway on a tubular welded frame scaffold approximately 31 feet above the ground level with no guardrail system, observed on or about September 19, 2014.     CORRECTED DURING INSPECTION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  a) DG Nicholas Auto Parts:  The employer did not provide scaffold safety training for employees performing masonry restoration services from a tubular welded frame scaffold, on or about 9/19/2014.   Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed  according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide:      a) DG Nicholas Auto Parts: Three employees were sawing off concrete coping from a building that was 31 feet high. They were using a 35-foot high supported tubular welded frame spring lock scaffold which was not tied off to a sturdy structure to prevent from tipping or dislocation. Employees were exposed to fall hazards on or about September 19, 2014.                                                           CORRECTED DURING INSPECTION.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700