Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EVOL, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EVOL, LTD. in G STREET & MONAHAN WAY WPAFB, FAIRBORN, OH 45324 (NAICS 237110). OSHA activity number 339970394.

Watch Evol, LTD. — free Get an email when a new federal OSHA severe-injury report for Evol, LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
EVOL, LTD.
Site address
G STREET & MONAHAN WAY WPAFB
City
FAIRBORN
State
OH
ZIP
45324
Mailing
535 SIEF RD., PIKETON, OH 45661
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.   Workers were observed engaged in excavation/trenching operations installing 8.0 inch ductile sewer pipes to bypass an existing manhole. Worker(s) were exposed to potential cave-in and struck-by hazards from loose spoils that were on the located on the south side of the 16.0 foot deep excavation.
Recent events (1)
  • — Z (S) $2000

1926.651 K01

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:   Workers were engaged in excavation/trenching operations installing 8.0 inch, SDR 35, ductile sewer pipes to bypass an existing manhole separating a sanitary and storm water piping system. Worker(s) were exposed to potential cave-in and struck-by hazards and regular and frequent inspections by a competent person were not conducted to ensure that the jobsite, materials, and equipment such as cave-in protection systems and proper distance of spoil piles were maintained and utilized in a safe manner.
Recent events (1)
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance paragraph (b) or (c) of 29 CFR 1926.652.    Workers were engaged in excavation/trenching operations installing new 8.0 inch SDR 35, ductile sewer pipes to bypass an existing manhole and separate the sanitary and storm water systems. Worker(s) were exposed to potential cave-in hazards in that a proper cave-in protection system was not utilized.
Recent events (1)
  • — Z (S) $2800