2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PHILIP J. STOFANAK, JR., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PHILIP J. STOFANAK, JR., INC. in 176 NAZARETH PIKE, BETHLEHEM, PA 18020 (NAICS 337110). OSHA activity number 339981433.

Watch Philip J. Stofanak, JR., INC. — free Get an email when a new federal OSHA severe-injury report for Philip J. Stofanak, JR., INC. is published. One employer, no account, unsubscribe in one click.
Site address
176 NAZARETH PIKE
City
BETHLEHEM
State
PA
ZIP
18020
Mailing
176 NAZARETH PIKE, BETHLEHEM, PA 18020
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
45
Ownership type
A

4 citations on file for this inspection.

1910.212 A05

Serious Gravity 1 2 instances 40 exposed
Issued
Penalty
Initial $1517.00 · Current $1138.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level.   a) Frame Assembly Work Shop Area: On or about October 2, 2014, an employee used a 4 feet (stand up) Dayton pedestal fan which had fan blade guard openings larger than ½ inch, exposing employees to a cutting/amputation hazard.     b) Doors & Drawers Work Shop Area: On or about October 2, 2014, an employee used a 5 feet (stand up) Diehl pedestal fan which had fan blade guard openings larger than ½ inch, exposing employee to a cutting/amputation hazard.
Recent events (2)
  • — I (S) $1137.75
  • — Z (S) $1517

1910.213 I01

Serious Gravity 5 2 instances 40 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1785.00 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded    a) The Production Work Area: On or about October 2, 2014, a Crescent vertical band saw with a 3-inch portion of the blade not completely enclosed was used by employees, exposing the operator/employee to a point-of-operation/cutting hazard.      b) The Assemblers Work Area: On or about October 2, 2014, a Powermatic vertical band saw with a 1-inch portion of the blade not completely enclosed was used by employees, exposing the operator/employee to a point-of-operation/cutting hazard.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2380

1910.213 P04

Serious Gravity 1 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1339.00 Reduced
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:  a) Doors and Drawers Work Shop Area: On or about October 2, 2014, an employee used a belt sander that had an unguarded belt, exposing employees to an in-running nip point.
Recent events (2)
  • — I (S) $1338.75
  • — Z (S) $1785

1910.305 G02 III

Serious Gravity 1 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1339.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a) Frame Assembly Work Shop Area: On or about October 2, 2014, a Bridgewood Shaper machinery was in use by an employee which had its electrical service wiring without proper strain relief which placed the wiring's tension onto the terminal screws.
Recent events (2)
  • — I (S) $1338.75
  • — Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339981433.