Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TORRES MASONRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TORRES MASONRY in 1331 N. 377, ROANOKE, TX 76262 (NAICS 238140). OSHA activity number 339982290.

Watch Torres Masonry — free Get an email when a new federal OSHA severe-injury report for Torres Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
TORRES MASONRY
Site address
1331 N. 377
City
ROANOKE
State
TX
ZIP
76262
Mailing
611 N CIRCLE DR, ARLINGTON, TX 76010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.   On or about October 2, 2014, the employer did not ensure that a ladder was provided on the tubular welded scaffold to allow employees to safely access or egress the scaffold, exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $1600

1926.452 C04

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur.   On or about October 2, 2014, the employer did not ensure that scaffold components were locked together by locking pins when using a forklift to drop off the bucket of mortar exposing employees to scaffold collapse and fall hazard.
Recent events (1)
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.   On or about October 2, 2014, the employer did not ensure that guardrails were installed along all open sides, corners and end frames of the scaffold working platforms exposing employees to unprotected fall hazards.
Recent events (1)
  • — Z (S) $2000

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.   On or about October 2, 2014, employees engaged in masonry activities who work from a tubular welded frame scaffold was not trained by the employer to recognize the hazards.
Recent events (1)
  • — Z (S) $1600

View TORRES MASONRY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339982290.