BEAUMONT, TX —
OSHA Inspection: MCLEOD MACHINE WORKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCLEOD MACHINE WORKS, INC. in 4717 SOUTH MLK PARKWAY, BEAUMONT, TX 77705 (NAICS 332999). OSHA activity number 339989220.
Where did this inspection happen?
- Establishment
- MCLEOD MACHINE WORKS, INC.
- Site address
- 4717 SOUTH MLK PARKWAY
- City
- BEAUMONT
- State
- TX
- ZIP
- 77705
- Mailing
- 4717 SOUTH MLK PARKWAY, BEAUMONT, TX 77705
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 30
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Inside the VAC building, the procedures were not utilized when employees had to change the blade for the Cosen model C420NC horizontal saw.
Recent events (3)
- — R (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $4900.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: a) The energy control procedures for the Cosen C420NC horizontal band saw did not outline the scope, purpose, authorization, rules and techniques.
Recent events (3)
- — R (S) $4900
- — C (S) $2975
- — Z (S) $2975
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) The energy control procedures for the Cosen C420NC horizontal band saw did not specifically outline how to shut down and isolate the hazardous energies. b) The energy control procedures for the Siloma OL400A horizontal band saw did not specifically outline how to shut down and isolate the hazardous energies
Recent events (3)
- — R (S) $0
- — C (S) $4900
- — Z (S) $4900
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) The operator of the Cosen horizontal band saw had not received energy control training.
Recent events (3)
- — R (S) $0
- — C (S) $2975
- — Z (S) $2975
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Inside the manufacturing facility by the offices, the Roll-In-Saw band saw had approximately 7 inches of exposed blade. b) Inside the C & C shop, the Roll-In-Saw band saw had approximately 8 inches of exposed blade.
Recent events (3)
- — R (S) $2450
- — C (S) $4900
- — Z (S) $4900
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339989220.