JOINT BASE LEWIS MCCHORD, WA —
OSHA Inspection: TODD ROBINSON PAINTING, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TODD ROBINSON PAINTING, INC. in 4TH DIVISION DRIVE AND COLLIER AVE.; TEMF NORTH, JOINT BASE LEWIS MCCHORD, WA 98433 (NAICS 238320). OSHA activity number 339996324.
Where did this inspection happen?
- Establishment
- TODD ROBINSON PAINTING, INC.
- Site address
- 4TH DIVISION DRIVE AND COLLIER AVE.; TEMF NORTH
- City
- JOINT BASE LEWIS MCCHORD
- State
- WA
- ZIP
- 98433
- Mailing
- 5030 JOPPA STREET SW, TUMWATER, WA 98512
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.405 A02 II I
- Issued
- Penalty
- Initial $1366.00 · Current $683.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a) Tactical Equipment Maintenance Facility North; Maintenance Bay; On or about October 8, 2014, a Genie lift #G27304 was parked on a blue SJTW#12 extension cord which was supplying power to another Genie lift receptacle. This receptacle provided power to a compressor for a spray painting gun which was used to spray primer on overhead beams, HVAC system vents and pipes.
Recent events (2)
- — I (O) $683
- — Z (S) $1366
1926.501 B04 II
- Issued
- Penalty
- Initial $2731.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. a) Tactical Equipment Maintenance Facility North; Maintenance Bay; On or about October 8, 2014, a concrete maintenance pit measuring approximately 5 feet 7 inches deep by 42 ¼ inches wide by 40 feet long was not guarded by covers.
Recent events (2)
- — I (O) $0
- — Z (S) $2731
More inspections at TODD ROBINSON PAINTING, INC.
TUMWATER, WA—2013-03-05 00:00:00
TODD ROBINSON PAINTING INC
LAKE TAPPS, WA—2009-01-07 00:00:00
TODD ROBINSON PAINTING INC
ORTING, WA—2009-01-05 00:00:00
TODD ROBINSON PAINTING INC
View TODD ROBINSON PAINTING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
RIVIERA BEACH, FL—2026-07-09
PINMAR USA INC.
REDDING, CA—2026-07-08
NICK MAYS PAINTING INC
MILWAUKEE, WI—2026-07-08
CALICHAPIN PAINTING AND LITTLE MORE, LLC
More inspections in WA
FREELAND, WA—2026-07-10
WA317992031 - NORTH RIVER CONCRETE PUMPING LLC
ENUMCLAW, WA—2026-07-10
WA317992030 - PARKER HANNIFIN CORP
PATERSON, WA—2026-07-10
WA317992032 - COLUMBIA WATER & POWER DISTRICT
LONGVIEW, WA—2026-07-10
WA317992033 - UNITED STATES BAKERY DBA FRANZ FAMILY BAKERIE
FERNDALE, WA—2026-07-09
WA317992021 - FOUR SEASONS CONTRACTOR LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339996324.