Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPOOR ELECTRIC INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPOOR ELECTRIC INC. in 365 UPTOWN BLVD, CEDAR HILL, TX 75104 (NAICS 238210). OSHA activity number 340027291.

Watch Spoor Electric INC. — free Get an email when a new federal OSHA severe-injury report for Spoor Electric INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SPOOR ELECTRIC INC.
Site address
365 UPTOWN BLVD
City
CEDAR HILL
State
TX
ZIP
75104
Mailing
443 ASTON DRIVE, SUNNYVALE, TX 75182
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1150.00 Reduced
29 CFR 1926.453(b)(2)(iv): Employees shall always stand firmly on the floor of the basket, and shall not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position:    This violation most recently occurred on or about October 21, 2014 at a worksite located at 365 Uptown Boulevard, Cedar Hill, Texas 75104; where at least one employee working on a aerial lift climbed on the edge of the basket to repair a lighting fixture.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2800

1926.453 B02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.453(b)(2)(v): Personal fall arrest system was not worn or attached to the boom or basket when working from an aerial lift:  This violation most recently occurred on or about October 21, 2014 at a worksite located at 365 Uptown Boulevard, Cedar Hill, Texas 75104; where at least one employee working on a aerial lift was not wearing a personal fall arrest system to prevent from falling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SPOOR ELECTRIC INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340027291.