Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PEACE RIVER DISTRIBUTING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEACE RIVER DISTRIBUTING, INC. in 9400 PIPER ROAD, PUNTA GORDA, FL 33982 (NAICS 424810). OSHA activity number 340029867.

Watch Peace River Distributing, INC. — free Get an email when a new federal OSHA severe-injury report for Peace River Distributing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9400 PIPER ROAD
City
PUNTA GORDA
State
FL
ZIP
33982
Mailing
9400 PIPER ROAD, PUNTA GORDA, FL 33982
Inspection type
Planned (H)
Scope
Records only (C)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424810
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.37(b)(2):  Each exit must be clearly visible and marked by a sign reading "Exit."  (A)  In the warehouse where multiple exits are provided, each exit was not clearly visible and marked as required, on or about October 28, 2014. -
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.37 B04

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(4):  Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  (a). In the warehouse area no signage for directional travel was posted for the exit routes, on or about October 28, 2014.  (b). In the warehouse area the exit discharge was not immediately apparent along the warehouse south wall, on or about October 28, 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2520.00 Reduced
29 CFR 1910.106(d)(7)(i):  Suitable fire control devices, such as small hose or portable fire extinguishers, were not available at locations where flammable or combustible liquids were stored.  (a). At the fueling area where class-3 flammable fuel is stored and distributed for use by the delivery vehicles, no fire extinguishers or any other fire control devices were provided, on or about October 28, 2014.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.303 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  (a). At the forklift battery charging area clear and unobstructed access was not provided for each of the 480 volt power disconnects, on or about October 28, 2014.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.37 B06

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a suface value of at least five foot-candles (54 lux) by a reliable light source:  (a). The Exit sign at the entrance of the warehouse area from the administration area was no illuminated, on or about October 28, 2014.  (b). The Exit sign at the rear exit by human resources office was not illuminated, on or about October 28, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340029867.