Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTHSIDE AQUATICS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHSIDE AQUATICS LLC in 7610 COUNTS MASSIE, MAUMELLE, AR 72113 (NAICS 453910). OSHA activity number 340043777.

Watch Northside Aquatics LLC — free Get an email when a new federal OSHA severe-injury report for Northside Aquatics LLC is published. One employer, no account, unsubscribe in one click.
Site address
7610 COUNTS MASSIE
City
MAUMELLE
State
AR
ZIP
72113
Mailing
11 ASPEN COVE, MAUMELLE, AR 72113
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453910
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:       On or about October 31, 2014, employees pouring chemicals such as muriatic acid and sodium hypochlorite from one gallon containers into secondary containers were exposed to the hazard of splashing chemicals into their eyes without an emergency eye wash station to immediately flush their eyes with water.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:       On or about October 31, 2014, the employer had not developed and implemented a written hazard communication program for employees working with sodium hypochlorite and muriatic acid.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    On or about October 31, 2014, the employer had not provided information and training to employees working with chemicals such as but not limited to sodium hypochlorite and muriatic acid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:         On or about October 31, 2014 a breaker box located in the area behind the fish tanks had two unused openings on the lower right side. Employees accessing the breaker box to reset breakers were exposed to the hazards of contacting energized electrical parts.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:     On or about October 31, 2014 flexible cords supplying power to electronic ballasts for fluorescent lighting above the tanks were spliced to conductors on the ballast.   Strain relief was not provided to prevent pull from being directly transmitted to joints or terminal screws.  This condition exposed employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about October 31, 2014, breakers inside the breaker box located behind the fish tanks were not marked to indicate the circuit or equipment protected by the breaker.  This condition exposed employees to the hazard of no being able to locate the disconnecting means to equipment such as lights and pumps in the event of an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340043777.