BELOIT, WI —
OSHA Inspection: DRAEVING MACHINE TOOL, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DRAEVING MACHINE TOOL, INC. in 2710 PRAIRIE AVENUE, BELOIT, WI 53511 (NAICS 333517). OSHA activity number 340054824.
Where did this inspection happen?
- Establishment
- DRAEVING MACHINE TOOL, INC.
- Site address
- 2710 PRAIRIE AVENUE
- City
- BELOIT
- State
- WI
- ZIP
- 53511
- Mailing
- 2710 PRAIRIE AVENUE, BELOIT, WI 53511
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $850.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, any parts of which were seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: On or about November 3, 2014, drive pulleys were not guarded on the Heald Bore-Matic boring machines (Models 47-A and 49).
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2040.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: On or about November 3, 2014, energy control procedures were not utilized during set-up activities on CNC machines. The list of which includes, but is not limited to. a) The Hardinge CNC Lathe-model CS 65, serial no. CLT-363-C65 b) The Kitamura CNC Mill-model Mycenter 3X, serial no. 11396
Recent events (2)
- — I (S) $1400
- — Z (S) $2040
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about November 3, 2014, lockout or tagout devices were not affixed to energy isolating devices on CNC machines during set-up activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The employer had not provided employees with effective information and training on the details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information: On or about November 3, 2014, the employer had not provided affected employees with training on the new label elements and Safety Data Sheet (SDS) format associated with the revised Hazard Communication Standard (HCS 2012).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333517)
THREE RIVERS, MI—2026-06-16
W F WELLS INC
EVANSVILLE, IN—2026-06-09
HOOSIER STAMPING
RENO, NV—2026-06-04
THE LINCOLN ELECTRIC COMPANY
SPARKS, NV—2026-05-13
SAMCO FABRICATION LLC
CHICAGO, IL—2026-04-28
INDUSTRIAL MAINTENANCE, WELDING AND MACHINING COMPANY, INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC