NORTH CHARLESTON, SC —
OSHA Inspection: OE ENTERPRISES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OE ENTERPRISES, INC. in 3725 RIVERS AVE. SUITE 2, NORTH CHARLESTON, SC 29405 (NAICS 561720). OSHA activity number 340073030.
Where did this inspection happen?
- Establishment
- OE ENTERPRISES, INC.
- Site address
- 3725 RIVERS AVE. SUITE 2
- City
- NORTH CHARLESTON
- State
- SC
- ZIP
- 29405
- Mailing
- 348 ELIZABETH BRADY ROAD, HILLSBOROUGH, NC 27278
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561720
- Employees
- 16
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $1530.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) East wall of the Housekeeping Office: A 120 volt Wiremold relocatable power tap designed and listed to provide power to high concentrations of low powered loads such as computers, printers, T.V.s, radios, etc. was instead used to provide power to high powered loads such as a Rival microwave oven; a Summit compact refrigerator; and a Mr. Coffee - coffee maker. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1530
- — Z (S) $3060
1910.304 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: a) East wall of the Housekeeping Office: A Wiremold relocatable power tap used to power a Rival microwave oven (8.75 amps.); a Summit compact refrigerator (1.05 amps); and a Mr. Coffee - coffee maker (7.5 amps), with a total of 17.3 amps, which was larger amperage than the power tap's rated 15 amps. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Workplace: The employer could not produce a written hazard communication program on site which covered employees working with hazards such as Envirox Orange Concentrate 117 cleaner, Betco AX-it baseboard cleaner and stripper, and Lynx Floor Finish Remover. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at OE ENTERPRISES, INC.
BURLINGTON, NC—2012-06-05 00:00:00
OE ENTERPRISES, INC
View OE ENTERPRISES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561720)
PALM BAY, FL—2026-07-10
ASCEND BUILDING SERVICES, LLC
NOLENSVILLE, TN—2026-07-08
BUSY BS RESIDENTIAL CLEANING COMPANY
TACOMA, WA—2026-07-07
WA317991946 - COASTAL BUSINESS SERVICES GROUP INC
POULSBO, WA—2026-07-07
WA317991849 - SIMPLY HOUSE CLEANING LLC
DIXON, CA—2026-07-07
SANITATION PROCESS CONTROL, LLC
More inspections in SC
GREENVILLE, SC—2026-07-09
77570 - SHARPSHOOTERS INDOOR RANGE INC
NORTH CHARLESTON, SC—2026-07-09
77569 - RAYCAP INC
SUMMERVILLE, SC—2026-07-09
77568 - RACK ROOM SHOES
DENMARK, SC—2026-07-08
77567 - PEGASUS HOME FASHIONS
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340073030.