WINNETKA, IL —
OSHA Inspection: CHICAGO CAPITAL REAL ESTATE INVESTMENT COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHICAGO CAPITAL REAL ESTATE INVESTMENT COMPANY in 1248 SCOTT AVE., WINNETKA, IL 60093 (NAICS 238350). OSHA activity number 340074251.
Where did this inspection happen?
- Establishment
- CHICAGO CAPITAL REAL ESTATE INVESTMENT COMPANY
- Site address
- 1248 SCOTT AVE.
- City
- WINNETKA
- State
- IL
- ZIP
- 60093
- Mailing
- 913 GREEN BAY ROAD, WINNETKA, IL 60093
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 5
- Ownership type
- A
Citations
15 citations on file for this inspection.
1926.300 B01
- Issued
- Penalty
- Initial $2400.00 · Current $1080.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) The cutting blade on a portable Hitachi motorized miter saw provided for employee use was not guarded. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1080
- — Z (S) $2400
1926.300 B02
- Issued
- Penalty
- Initial $2400.00 · Current $1080.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded. a) The belt and pulley on a portable Delta table saw provided for employee use were not guarded to prevent contact with the moving parts. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1080
- — Z (S) $2400
1926.304 F
- Issued
- Penalty
- Initial $2400.00 · Current $1080.00 Reduced
General-duty citation text
29 CFR 1926.304(f): Sections 4.1.2 (a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f) circular handfed rip saws were not guarded by an automatically adjusting hood which completely encloses that portion of the saw above the table and above the material being cut: a) A Delta table saw was not equipped with a blade guard when provided for employee use to rip lumber. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $1080
- — Z (S) $2400
1926.304 F
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(f): Sections 4.1.2 (b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f) circular handfed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) A Delta table saw was not equipped with a spreader when provided for employee use to rip lumber. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.304 F
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(f): Sections 4.1.2 (c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f) circular handfed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) A Delta table saw was not equipped with non-kickback fingers or dogs when provided for employee use to rip lumber. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Penalty
- Initial $1600.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) 120v outlet/junction box mounted to a workbench for employee use at the site was not guarded or otherwise protected to prevent accidental contact with energized electrical parts. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $720
- — Z (S) $1600
1926.404 F11 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(11)(iii): All non-current carrying metal parts of portable equipment and fixed equipment including their associated fences, housings, enclosures and supporting structures were not grounded: a) The non-current carrying metal parts of a portable Delta table saw provided for employees use were not grounded. b) The non-current carrying metal parts of a portable Hitachi motorized miter saw provided for employee use were not grounded. No abatement certification or documentation is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(b)(2): Outlet boxes were not provided with covers, faceplates, or fixture canopies: a) The outlet box used to house a power switch for a portable Delta table saw did not have a cover exposing the employees to accidental contact with energized electrical parts. No abatement certification or documentation is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Flexible cords provided for employee use did not have strain relief to prevent pull from being directly transmitted to joints and terminal screws. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.416 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) A worn and frayed electrical extension cord was used to supply electricity to tools and equipment at the site. No abatement certification or documentation is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 A06
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design: a) The employer did not ensure that scaffolding provided for employee use at the site was erected under the supervision and direction of a competent person qualified in scaffolding erection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1260
- — Z (S) $2800
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels was not fully planked or decked between front uprights and the guardrail supports: a) Employees were exposed to the hazard of falling approximately 20 feet while working from scaffolding platforms that were not fully planked. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $900
- — Z (S) $2000
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Employees were working from a tubular welded frame scaffolding at an elevation of approximately 20 feet where the legs did not have base plates and were on pieces and stacks of wood. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F06
- Issued
- Penalty
- Initial $2000.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). a) An energized power line of 120/240 volts, servicing a house was less than three feet from the welded frame scaffold from which employees were using. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $900
- — Z (S) $2000
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1260.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Employees were exposed to the hazard of falling approximately 20 feet while working from scaffolding without the benefit of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1260
- — Z (S) $2800
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340074251.