Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DRS TECHNOLOGIES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DRS TECHNOLOGIES in 246 AIRPORT ROAD, JOHNSTOWN, PA 15904 (NAICS 335999). OSHA activity number 340075530.

Watch DRS Technologies — free Get an email when a new federal OSHA severe-injury report for DRS Technologies is published. One employer, no account, unsubscribe in one click.
Establishment
DRS TECHNOLOGIES
Site address
246 AIRPORT ROAD
City
JOHNSTOWN
State
PA
ZIP
15904
Mailing
246 AIRPORT ROAD, JOHNSTOWN, PA 15904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
345
Ownership type
A

5 citations on file for this inspection.

1910.132 E

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $3000.00 · Current $1500.00 Reduced

Hazardous substances 02301591

29 CFR 1910.132(e):  Defective or damaged personal protective equipment was used:    a) CCAC room, On or about November 10, 2104 - Employees wore torn and ripped leather gloves when hand dipping connectors into tin/lead solder pot.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.1000 A02

Serious Gravity 5 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $2500.00 Reduced

Hazardous substances 02300731

29 CFR 1910.1000(a)(2):  Employee(s) were exposed to airborne concentrations of antimony and copper fumes as listed in Table Z-2 in excess of 0.50 mg/m3 and 0.100mg/m3, respectively, as an 8-hour Time Weighted Average (TWA) concentration:    a)  CCAC Room, On or about December 3, 2014 -  The employer did not ensure that no employee was exposed to an airborne concentration of antimony in excess of 0.50 mg/m3 of air calculated as an 8-hour TWA exposure.  An employee operating the wave solder equipment was exposed to antimony in air concentration of 0.51 mg/m3 calculated as an 8-hour TWA.  Zero exposure was assumed for any unsampled time when calculating the 8-hour TWA.  The exposure was 1.02 times the permissible exposure limit (PEL) of 0.50 mg/m3.    b)   CCAC Room, On or about December 3, 2014 -  The employer did not ensure that no employee was exposed to an airborne concentration of copper fume in excess of 0.100 mg/m3 of air calculated as an 8-hour TWA exposure.  An employee operating the wave solder equipment was exposed to copper fume in air concentration of 0.103 mg/m3 calculated as an 8-hour TWA.  Zero exposure was assumed for any unsampled time when calculating the 8-hour TWA.  The exposure was 1.03 times the permissible exposure limit (PEL) of 0.100 mg/m3.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.1000 E

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 02300731

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1010.1000 (a) through (d):   a)  CCAC Room, On or about December 3, 2014 -  The employer did not ensure that feasible administrative or engineering controls were implemented to keep employee exposure to airborne antimony at or below the permissible exposure level of 0.50 mg/m3 as an 8-hour time-weighted average (TWA) exposure.  An employee operating the wave solder equipment was exposed to antimony in air concentration of 0.51 mg/m3 calculated as an 8-hour TWA.  Zero exposure was assumed for any unsampled time when calculating the 8-hour TWA.  The exposure was 1.02 times the permissible exposure limit (PEL) of 0.50 mg/m3.  b)  CCAC Room, On or about December 3, 2014- The employer did not ensure that feasible administrative or engineering controls were implemented to keep employee exposure to airborne copper fumes at or below the permissible exposure level of 0.100 mg/m3 as an 8-hour time-weighted average (TWA) exposure.  An employee operating the wave solder equipment was exposed to copper fumes in air concentration of 0.103 mg/m3 calculated as an 8-hour TWA.  Zero exposure was assumed for any unsampled time when calculating the 8-hour TWA.  The exposure was 1.03 times the permissible exposure limit (PEL) of 0.100 mg/m3.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1025 H01

Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances BWPB

29 CFR 1910.1025(h)(1):  All surfaces were not maintained as free as practicable of accumulations of lead:  a) CCAC room, On or about December 3, 2014 - The presence of lead was collected on table surfaces, ESD cart, wave solder machine, and workstations.   The employer did not keep the surfaces as free as practicable from lead accumulations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1025 L01 I

Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1592BWPB

29 CFR 1910.1025(l)(1)(i): Each employer who had a workplace in which there was a potential exposure to airborne lead at any level did not inform employees of the content of Appendices A and B of this regulation:   a) CCAC room, On or about December 3, 2014 -  Employees were unaware of lead symptoms and health hazards associated with the solder.  The employees were not provided this information provided in appendices A and B of the lead regulation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DRS TECHNOLOGIES's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340075530.