SEDALIA, MO —
OSHA Inspection: PK PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PK PRODUCTS in 32576 TATUM LOOP, SEDALIA, MO 65301 (NAICS 332999). OSHA activity number 340090265.
Where did this inspection happen?
- Establishment
- PK PRODUCTS
- Site address
- 32576 TATUM LOOP
- City
- SEDALIA
- State
- MO
- ZIP
- 65301
- Mailing
- 32576 TATUM LOOP, SEDALIA, MO 65301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 17
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 D01
- Issued
- Penalty
- Initial $1020.00 · Current $714.00 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. (a) Main Building: Employees were exposed to overhead hazards as the area above the Time Clock in the Parts Area was being used for storage and there was no posted load rating. (b) Main Building: Employees were exposed to overhead hazards as the area above the Acetylene tank storage area was being used for storage and there was no posted load rating. (c) Main Building: Employees were exposed to overhead hazards as the area above the Oxygen tank storage area was being used for storage and there was no posted load rating. (d) East Building: Employees were exposed to overhead hazards as the area above the restrooms was being used for storage and there was no posted load rating.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $952.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Throughout facility: Employees were exposed to electrical and other hazards as there were no machine specific lockout tagout procedures for machines that had more than one power source, and were hard wired in; or machines that were hard wired in and did not have the disconnects located on the machine, such as, but not limited to, the Corrugation Machine, and the Uni-Hydro Inc. Ironworker, were not descriptive of the type of machine, the location to lock and tag out the piece of equipment and steps to reenergize machine following maintenance completion.
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1910.178 P01
- Issued
- Penalty
- Initial $1360.00 · Current $952.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) Parts Area: Employees were exposed to the hazard of the Clark Forklift not being removed from service until restored to a safe operating condition as it did not having a working horn. (b) Head Shop or East Building: Employees were exposed to the Clark Forklift not being removed from service until restored to a safe operating condition as it did not have a nonslip surface on the break pedal.
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1910.303 B01
- Issued
- Penalty
- Initial $1360.00 · Current $952.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): (a) East Building: Employees were exposed to electrical hazards as the electrical cord for the foot pedal for the Summit Shear had a damaged electrical cord.
Recent events (2)
- — I (S) $952
- — Z (S) $1360
More inspections in this industry (NAICS 332999)
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340090265.