Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ST. JUDE MASONRY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ST. JUDE MASONRY, LLC in 1755 WYNDALE STREET, HOUSTON, TX 77030 (NAICS 238140). OSHA activity number 340090703.

Watch ST. Jude Masonry, LLC — free Get an email when a new federal OSHA severe-injury report for ST. Jude Masonry, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1755 WYNDALE STREET
City
HOUSTON
State
TX
ZIP
77030
Mailing
5454 SOUTH CROOKED CREEK DR, HOUSTON, TX 77017
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
18
Ownership type
A

4 citations on file for this inspection.

1926.451 A06

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person:    At 1755 Wyndale Street, Houston TX; the employer erected a tubular welded scaffold that was not designed by a qualified person with deficiencies such as but not limited to not fully plank between the uprights, missing safe means of access and missing base plates, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights:       At 1755 Wyndale Street, Houston TX; employees used a tubular welded scaffold which was not fully planked/ decked between the uprights, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation:     At 1755 Wyndale Street, Houston, TX, on the sixth floor of the parking garage; employees used a tubular welded scaffold without base plates, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.       At 1755 Wyndale Street, Houston TX, on the sixth floor of the parking garage; employees used crossbraces to access tubular welded scaffold, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340090703.