DORAL, FL —
OSHA Inspection: PP ALL CORP
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PP ALL CORP in 8401 NW 33RD STREET, DORAL, FL 33166 (NAICS 238350). OSHA activity number 340097203.
Where did this inspection happen?
- Establishment
- PP ALL CORP
- Site address
- 8401 NW 33RD STREET
- City
- DORAL
- State
- FL
- ZIP
- 33166
- Mailing
- 4030 SW 111 AVENUE, MIAMI, FL 33165
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.25 A
- Issued
- Abate by
- Penalty
- Initial $2970.00 · Current $2970.00
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: On or about 11/20/14, at 8401 NW 33rd Street Lot 01/Block 02, employees conducting carpentry and forming work were exposed to slip, trip, and fall hazards due to construction material and debris not kept in an orderly fashion. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
- — Z (S) $2970
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $3960.00 · Current $3960.00
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about 11/20/14, at the above mentioned job site (Lot 01/Block 02), an employee on a 3rd floor overhang who was installing plywood with the use of a nail gun and not wearing eye protection was exposed to struck-by hazard. b. On or about 11/20/14, at the above mentioned job site (Lot 10/Block 03), an employee kneeling on the tie-beam of a 2nd floor removing nails with the use of a hammer and not wearing eye protection was exposed to a struck-by hazard. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
- — Z (S) $3960
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4950.00 · Current $4950.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about 11/20/14, at 8401 NW 33rd Street Lot 01/Block 02, employees who were installing plywood on the overhang of a 3rd floor without any means of fall protection were exposed to a fall hazard of approximately 24 feet. b. On or about 11/20/14, at the above mentioned job site (Lot 10/Block 03), an employee kneeling on a 2nd floor tie-beam who was removing nails from a form board without a means of fall protection was exposed to a fall hazard of approximately 17 feet. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
- — Z (S) $4950
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $6930.00 · Current $6930.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: a. On or about 11/20/14, at 8401 NW 33rd Street Lot 01 / Block 02, employees who were not instructed to recognize fall hazards prior to installing and/or removing plywood boards were exposed to a fall hazard. b. On or about 11/20/14, at 8401 NW 33rd Street Lot 10 / Block 03, employees who were not instructed to recognize fall hazards prior to installing and/or removing plywood boards were exposed to a fall hazard. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
- — Z (S) $6930
1926.701 B
- Issued
- Abate by
- Penalty
- Initial $4950.00 · Current $4950.00
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about 11/20/14, at 8401 NW 33rd Street Lot 01/Block 02, employees were exposed to impalement hazards while installing sheathing on a 3rd floor overhang of a residential home, when uncapped rebars were present directly underneath from where they conducted the work. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (1)
- — Z (S) $4950
1926.1052 C01 II
- Issued
- Penalty
- Initial $6930.00 · Current $6930.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge: On or about 11/20/14, at 8401 NW 33rd Street Lot 01/Block 02, employees were using a stairwell to access the 3rd floor level of a new residential building in construction for the purpose of installing plywood on the overhang and were exposed to fall hazards of approximately 10.6 feet due to lack of a stair rail system..
Recent events (1)
- — Z (S) $6930
1926.1052 C01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, was not equipped with at least one handrail: On or about 11/20/14, at 8401 NW 33rd Street Lot 01/Block 02, employees were using a stairwell to access the 3rd floor level of a new residential building in construction for the purpose of installing plywood on the overhang and were exposed to fall hazards due to lack of a hand rail.
Recent events (1)
- — Z (S) $0
More inspections at PP ALL CORP
DORAL, FL—2015-06-02 00:00:00
PP ALL CORP
DAVIE, FL—2015-05-14 00:00:00
PP ALL CORP
MIAMI, FL—2014-10-09 00:00:00
PP ALL CORP
View PP ALL CORP's full OSHA safety record →
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source