Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PEDRO VASQUEZ ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEDRO VASQUEZ ROOFING in 5116 GLEN MEADOW DRIVE, ARLINGTON, TX 76018 (NAICS 236115). OSHA activity number 340098292.

Watch Pedro Vasquez Roofing — free Get an email when a new federal OSHA severe-injury report for Pedro Vasquez Roofing is published. One employer, no account, unsubscribe in one click.
Site address
5116 GLEN MEADOW DRIVE
City
ARLINGTON
State
TX
ZIP
76018
Mailing
509 MULLIN STREET APT 27, ARLINGTON, TX 76014
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:     This violation occurred on November 21, 2014, at a work site located at 5116 Glen Meadow Drive, Arlington, Texas; employees using pneumatic nail guns were not protected from eye injuries by wearing protective eyewear.
Recent events (1)
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6-feet or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of '1926.502(k) developed and implemented.    This violation occurred on November 21, 2014, at a work site located at 5116 Glen Meadow Drive, Arlington, Texas; at least two employees, who were walking and working from the roof of a new residential building, were not protected from falling to the lower level by use of guardrail or personal fall arrest system.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.1053(b)(1):  When portable ladders were used for access to an upper landing surface, the ladder side rails was not extended at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    This violation occurred on November 21, 2014, at a work site located at 5116 Glen Meadow Drive, Arlington, Texas; employees used ladders that were not extended at least 3 feet above the upper landing to access the working area exposing the employees to a fall hazard.
Recent events (1)
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340098292.