Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHIMNEY.COM in 2400 MONROE ST., NE, WASHINGTON, DC 20006 (NAICS 238990). OSHA activity number 340102029.

Watch Chimney.Com — free Get an email when a new federal OSHA severe-injury report for Chimney.Com is published. One employer, no account, unsubscribe in one click.
Establishment
CHIMNEY.COM
Site address
2400 MONROE ST., NE
City
WASHINGTON
State
DC
ZIP
20006
Mailing
10 OLD BONIFANT RD., SILVER SPRING, MD 20905
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Roof -  On or about 11/13/2014, a worker not provided with fall protection was exposed to a 25 foot fall while installing a chimney flue liner.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:   a)  Roof -  On or about 11/13/2014, a worker was exposed to a 20 foot fall from the top of an aluminum extension ladder that projected only 2 feet above the edge of the roof and was not secured in place and provided with a grabrail.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600