SOUTH WINDSOR, CT —
OSHA Inspection: ALVA DRYWALL, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALVA DRYWALL, LLC in 14 TAMARACK AVENUE, SOUTH WINDSOR, CT 06074 (NAICS 238310). OSHA activity number 340108331.
Where did this inspection happen?
- Establishment
- ALVA DRYWALL, LLC
- Site address
- 14 TAMARACK AVENUE
- City
- SOUTH WINDSOR
- State
- CT
- ZIP
- 06074
- Mailing
- 41 JOHNSON STREET, WATERBURY, CT 06710
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about 11/25/2014 at the Melekote Medical Building Construction Project, employees were working from the 2nd floor and no fall protection system was in use at the front unguarded opening.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.502 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: On or about 11/25/2014 at the Melekote Medical Building Construction Project, employees were working from the second floor and the wire rope cable guardrail system was not at 42 inches, plus or minus 3 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D16 III
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: On or about 11/25/2014 at the Melekote Medical Building Construction Project, an employee was working from an aerial lift and using a personal fall protection system that was not rigged to prevent contact with lower levels.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.