Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOUR SEASONS: A DIVISION OF STANDARD MOTOR PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FOUR SEASONS: A DIVISION OF STANDARD MOTOR PRODUCTS, INC. in 500 INDUSTRIAL BLVD., GRAPEVINE, TX 76051 (NAICS 336312). OSHA activity number 340130178.

Watch Four Seasons: A Division OF Standard Motor Products, INC. — free Get an email when a new federal OSHA severe-injury report for Four Seasons: A Division OF Standard Motor Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 INDUSTRIAL BLVD.
City
GRAPEVINE
State
TX
ZIP
76051
Mailing
500 INDUSTRIAL BLVD., GRAPEVINE, TX 76051
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336312
Employees
180
Ownership type
A

4 citations on file for this inspection.

1910.212 A03 II

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Fan Clutch Cover Room, employees operating a 5 ton press brake without point of operation guarding were exposed to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $3000.00 · Current $3000.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Fan Clutch Cover Room, employees were exposed to electrical shock hazards when operating a 5-ton press where a two receptacle gang box was used to power electrical equipment that was not used in accordance with manufacturer direction.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $3000

1910.305 B01

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed.      Fan Clutch Cover Assembly Room, an electrical metal box on the east wall had two one-inch openings that were not covered exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:     Fan Clutch Cover Room, employees were exposed to electrical shock hazards when operating a 5-ton press where a two receptacle gang box was used to power electrical equipment that did not have strain relief.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340130178.