Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUCDUC, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DUCDUC, LLC in 535 MIGEON AVENUE, TORRINGTON, CT 06790 (NAICS 337127). OSHA activity number 340130632.

Watch Ducduc, LLC — free Get an email when a new federal OSHA severe-injury report for Ducduc, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DUCDUC, LLC
Site address
535 MIGEON AVENUE
City
TORRINGTON
State
CT
ZIP
06790
Mailing
535 MIGEON AVENUE, TORRINGTON, CT 06790
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
51
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2618.00 · Current $1833.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   A.  On or about December 16, 2014, Boiler Room:  The emergency exit from the boiler room to the General Production Shop floor was not identified with an illuminated exit sign.
Recent events (2)
  • — I (S) $1832.6
  • — Z (S) $2618

1910.213 C03

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $3927.00 · Current $2749.00 Reduced
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  A.  On or about December 5, 2014, General Production Shop:  The Delta X5 Unisaw table saw was not provided with anti-kickback fingers or dogs when used for ripping.
Recent events (2)
  • — I (S) $2748.9
  • — Z (S) $3927

1910.213 S06

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2618.00 · Current $1833.00 Reduced
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  A.  On or about December 16, 2014, Custom Shop:  At the Makita chop saw, significant amounts of sawdust had been allowed to accumulate near the saw, presenting a fire hazard.
Recent events (2)
  • — I (S) $1832.6
  • — Z (S) $2618

1910.304 G05

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1669.00 · Current $1168.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   A.  On or about December 16, 2014, Custom Shop:  The path to ground from the Westpointe 18" metal encased pedestal fan was not permanent, continuous and effective.  Employees using the fan were exposed to electric shock hazards.
Recent events (2)
  • — I (S) $1168.3
  • — Z (S) $1669

1910.132 D01

Other-than-serious 1 instance 45 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   A.  On or about December 16, 2014, facility-wide:  The employer had not conducted a workplace hazard assessment to determine what personal protective equipment would be necessary, including, but not limited to eye protection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DUCDUC, LLC's full OSHA safety record →