Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTHSTAR PULP AND PAPER CO. INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTHSTAR PULP AND PAPER CO. INC. in 89 & 99 GUION STREET, SPRINGFIELD, MA 01104 (NAICS 423930). OSHA activity number 340131473.

Watch Northstar Pulp AND Paper CO. INC. — free Get an email when a new federal OSHA severe-injury report for Northstar Pulp AND Paper CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
89 & 99 GUION STREET
City
SPRINGFIELD
State
MA
ZIP
01104
Mailing
P.O. BOX 1450, SPRINGFIELD, MA 01101
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
62
Ownership type
A

11 citations on file for this inspection.

1910.23 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $1925.00 Reduced
29 CFR 1910.23(a)(5): Every pit and floor opening was not adequately guarded by standard railing or any other effected means.     89 Guion Street, Springfield, MA: On or about December 11, 2014, CSHO observed a pit opening in the Bollegraf Bailer Room, which was not adequately guarded to prevent accidental dislodgement of metal decking exposing an employee to fall hazards.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3850

1910.23 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $0.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent).    89 Guion Street, Springfield, MA: On or about December 11, 2014, employees were observed working around the conveyor belt of a Bollegraaf Baler Machine that was more than 65 inches below floor grade with no guardrails installed to prevent accidental falls to lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1910.27 F

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1964.00 · Current $0.00 Reduced
29 CFR 1910.27(f): Ladders were not maintained in a safe condition or inspected regularly:    89 Guion Street, Springfield, MA:  On or about December 11, 2014, employees were observed working around a fixed ladder which was not maintained in safe manner exposing employee to slips, trips and fall hazards.    (a) Bollegraaf Baler room, fixed ladder on bailing machine, bent bottom rung.  (b) Bollegraaf Baler room, fixed ladder on bailing machine, forklift attachment stored at bottom of ladder.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1964

1910.110 F02 I

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $2310.00 · Current $0.00 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located in an area that minimized exposure to excessive temperature rise, physical damage, or tampering from unauthorized persons:    Parking Lot, 89 Guion Street, Springfield, MA: On or about December 11, 2014, seven 60 lb. liquefied petroleum gas cylinders were observed that were not secured to prevent tampering with or physical damage to them.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2310

1910.146 C01

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $2310.00 · Current $1155.00 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  89 & 99 Guion Street, Springfield, MA: On or about December 11, 2014, employer did not evaluate workplace to determine if there were any permit-required confined spaces.  (a) Bollegraaf  Baler room, machinery pit, below grade. (b) Enterprise Baler room, machinery pit, below grade.
Recent events (2)
  • — I (S) $1155
  • — Z (S) $2310

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $1925.00 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy:  89 Guion Street, Springfield, MA. On or about December 11, 2014: employer failed to provide energy control procedures for the Grey Guillotine cutter located in the  Bollegraaf Baler Room. These procedures failed to identify all specific steps to be followed by employees to isolate and disable the guillotine, to safely de-energize the equipment and control hazardous energy.  The procedure also lacked specific steps to ensure the blade was properly blocked in case of a sudden loss of hydraulic power.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3850

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  89 Guion Street, Springfield, MA: On or about December 11, 2014: employer had a lock out\tag out program in which no periodic inspections were conducted at least annually from that date by an authorized person to ensure that the procedures and requirements of the standard were being followed. Employer lock out\tag out program was revised in May of 2013 and no inspections of the program been conducted since that date.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 II

Serious Gravity 5 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $1925.00 Reduced
29 CFR 1910.219(e)(3)(ii): All guards for inclined belts shall be arranged in such a manner that a minimum clearance of seven (7) feet is maintained between belt and floor at any point outside of guard.   89 & 99 Guion Street, Springfield, MA: On or about December 11, 2014, CSHO observed inclined belts which were not guarded at all points below 7 feet above the floor.  (a) Bollegraaf Baler, lower end of belt, belt between floor and support not guarded. (b) Enterprise Baler,  unguarded conveyor rollers less than 7 ft. above working surface. (c) Cumberland Plastic Baler, white, lower conveyor belt guard damaged and not covering belt edge.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3850

1910.303 B08 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $1925.00 Reduced
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted.  89 Guion Street, Bollegraaf Baler room, 440V panel supplying the grey guillotine roll cutting machine, Springfield, MA: On or about December 11, 2014, employees were observed working around an electrical panel which was not firmly mounted to the surface it was secured to; exposing employees to electrical shocks and burns.
Recent events (2)
  • — I (S) $1925
  • — Z (S) $3850

1910.303 G02 II

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:   99 Guion Street,  Power Panel, American Baler, Springfield, MA: On or about December 15, 2014, employees were working at or around an electrical panel which was not guarded from physical damage.  Panel had visible physical damage to the outer casing which was powering a bailing machine exposing employees to electrical shocks and burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3850

1910.305 A02 X

Serious Gravity 5 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $1540.00 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords were not protected from accidental damage, as might be caused for example, by sharp corners, projections, and doorways or other pinch points:  89 Guidon St, Springfield, MA: On December 11 & 15, 2014 flexible cords were observed which were not protected from accidental damage as caused by vehicular traffic pinch points and sharp corners.  (a) Yellow, flexible, 100 ft. extension cord, running across parking lot under scale. (b) Red, flexible, 100 ft. extension cord, running across parking lot under scale. (c) Gray, flexible, electrical supply line, grey guillotine, bailing room.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340131473.