TULSA, OK —
OSHA Inspection: NEILSON MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NEILSON MANUFACTURING in 3517 CHARLES PAGE BLVD, TULSA, OK 74127 (NAICS 332312). OSHA activity number 340135383.
Where did this inspection happen?
- Establishment
- NEILSON MANUFACTURING
- Site address
- 3517 CHARLES PAGE BLVD
- City
- TULSA
- State
- OK
- ZIP
- 74127
- Mailing
- 3517 CHARLES PAGE BLVD, TULSA, OK 74127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 17
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.184 I01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material. On or about December 11, 2014 and at times prior thereto, employees were in use of synthetic web slings that were not marked to show rated capacities, exposing employees to struck by, crushed by hazards. Serious harm from the unknown weight rated straps and slings used to move large heavy steel for production work was located in the main bay of shop near the foreman's office.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.184 I09
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(i)(9): Synthetic web sling was not immediately removed from service for having snags, cuts and tears. On or about December 11, 2014 and at times prior to employees were exposed to struck by, crushed by hazards causing serious harm from unsafe use of damaged deteriorated straps and slings used to move large heavy steel for production work located in the main bay of shop near foreman's office.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). On or about December 11, 2014 and at times prior thereto, the employer did not ensure the in-going nip points of moving parts on the pulley of an air compressor were guarded exposing employees to caught-in hazards. The employees were exposed to struck by, caught in and pinch point hazards resulting in serious harm from unguarded moving parts of air compressor machine located near the break area and the main electrical control panel wall located just outside of the main office area.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.219 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt. On or about December 11, 2014 and at times prior thereto, the employer did not ensure belts of a pulley on an air compressor were guarded exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.243 C03
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel. On or about December 11, 2014 and at times prior to employees where exposed to struck by hazard from flying debris while using a hand grinder without a guard attachment in place. Instance 1; Back table in main production work room, near stack being worked on, grinder wheel in use unguarded. Instance 2; Center of main production work room welding table with hand grinder wheel in use unguarded.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.253 B02 IV
- Issued
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use. On or about December 11, 2014 and at times prior to employees were exposed to struck by explosion hazards from unattended acetylene and oxygen gas cylinder bottles not stored with cap covers on.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. On or about December 11, 2014 and at times prior thereto, the employer did not ensure each circuit in the panel box located along the main electrical control room was legibly marked indicating its purpose, exposing employees to electrical hazards. Instance one : First panel located on the left side of wall near break room area and air compressor station.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. On or about December 11, 2014 and at times prior thereto, the employer did not ensure openings in a panel box located near the break room were effectively closed, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: On or about December 11, 2014 and at times prior to employees were exposed to unsanitary and unsafe conditions for rest break area near uncovered exposure to live electrical wiring, unguarded air compressor with moving parts and dirty tables and floors where employees take rest with eat and drink break.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340135383.