On , OSHA opened a planned safety inspection of NEILSON MANUFACTURING in 3517 CHARLES PAGE BLVD, TULSA, OK 74127 (NAICS 332312). OSHA activity number 340135383.

Watch Neilson Manufacturing — free Get an email when a new federal OSHA severe-injury report for Neilson Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
3517 CHARLES PAGE BLVD
City
TULSA
State
OK
ZIP
74127
Mailing
3517 CHARLES PAGE BLVD, TULSA, OK 74127
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
17
Ownership type
A

9 citations on file for this inspection.

1910.184 I01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material.    On or about December 11, 2014 and at times prior thereto, employees were in use of synthetic web slings that were not marked to show rated capacities, exposing employees to struck by, crushed by hazards. Serious harm from the unknown weight rated straps and slings used to move large heavy steel for production work was located in the main bay of shop near the foreman's office.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.184 I09

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(i)(9): Synthetic web sling was not immediately removed from service for having snags, cuts and tears.  On or about December 11, 2014 and at times prior to employees were exposed to struck by, crushed by hazards causing serious harm from unsafe use of damaged deteriorated straps and slings used to move large heavy steel for production work located in the main bay of shop near foreman's office.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).    On or about December 11, 2014 and at times prior thereto, the employer did not ensure the in-going nip points of moving parts on the pulley of an air compressor were guarded exposing employees to caught-in hazards. The employees were exposed to struck by, caught in and pinch point hazards resulting in serious harm from unguarded moving parts of air compressor machine located near the break area and the main electrical control panel wall located just outside of the main office area.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.219 E01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt.  On or about December 11, 2014 and at times prior thereto, the employer did not ensure belts of a pulley on an air compressor were guarded exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C03

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel.    On or about December 11, 2014 and at times prior to employees where exposed to struck by hazard from flying debris while using a hand grinder without a guard attachment in place.    Instance 1; Back table in main production work room, near stack being worked on, grinder wheel in use unguarded.     Instance 2; Center of main production work room welding table with hand grinder wheel in use unguarded.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.253 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.    On or about December 11, 2014 and at times prior to employees were exposed to struck by explosion hazards from unattended acetylene and oxygen gas cylinder bottles not stored with cap covers on.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.     On or about December 11, 2014 and at times prior thereto, the employer did not ensure each circuit in the panel box located along the main electrical control room was legibly marked indicating its purpose, exposing employees to electrical hazards.    Instance one : First panel located on the left side of wall near break room area and air compressor station.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about December 11, 2014 and at times prior thereto, the employer did not ensure openings in a panel box located near the break room were effectively closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:  On or about December 11, 2014 and at times prior to employees were exposed to unsanitary and unsafe conditions for rest break area near uncovered exposure to live electrical wiring, unguarded air compressor with moving parts and dirty tables and floors where employees take rest with eat and drink break.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0