OSHKOSH, WI —
OSHA Inspection: NORTHERN ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHERN ELECTRIC, INC. in CLOW HALL, OSHKOSH, WI 54901 (NAICS 238210). OSHA activity number 340153436.
Where did this inspection happen?
- Establishment
- NORTHERN ELECTRIC, INC.
- Site address
- CLOW HALL
- City
- OSHKOSH
- State
- WI
- ZIP
- 54901
- Mailing
- 314 N. DANZ AVE, GREEN BAY, WI 54302
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.303 C02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.303(c)(2): Floor or bench mounted grinder(s) were not provided with work rests: On and before 12/22/14, a Buffalo 8" bench grinder used to deburr EMT conduit was not equipped with a work rest on the right side and the work rest on the left side was not adjusted to within 1/8" of the wheel to prevent material being pulled between the abrasive wheel and the wheel cover.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On 12/22/14, electrical components were used in applications that they were not listed or labeled for including: a) In the jobsite conference room, the employer had a 4 inch gang box that was used as a pendant box. The gang box was not listed and labeled to be used as a pendant box. b) Located in the basement of the project and next the electrician's work bench, a 220v range plug connector designed to be permanently mounted to wall structures was not secured and used as a cord and plug to welding equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.416 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.416(e)(2): Extension cords were fastened with staples, hung from nails, or suspended by wire: On 12/22/14, the electric cord conductors used for temporary electric lighting throughout the project were suspended by using uncoated tie wire creating damaged to electrical cords.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at NORTHERN ELECTRIC, INC.
MERRITT ISLAND, FL—2017-06-01 00:00:00
NORTHERN ELECTRIC, INC.
BOULDER CITY, NV—2016-10-25 00:00:00
NORTHERN ELECTRIC, INC.
BOULDER CITY, NV—2016-06-29 00:00:00
NORTHERN ELECTRIC INC.
STURGEON BAY, WI—2013-05-07 00:00:00
NORTHERN ELECTRIC INC
KINGSPORT, TN—2012-10-17 00:00:00
NORTHERN ELECTRIC, INC.
View NORTHERN ELECTRIC, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340153436.