Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HUNTS MASONRY & RESTORATION COMPANY, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of HUNTS MASONRY & RESTORATION COMPANY, INC. in 2226 MURPHY STREET, SHREVEPORT, LA 71103 (NAICS 238140). OSHA activity number 340154434.

Watch Hunts Masonry & Restoration Company, INC. — free Get an email when a new federal OSHA severe-injury report for Hunts Masonry & Restoration Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2226 MURPHY STREET
City
SHREVEPORT
State
LA
ZIP
71103
Mailing
760 BESTER STREET, SHREVEPORT, LA 71107
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.300 A

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition:    On or about December 10, 2014, at 2226 Murphy Street, Shreveport, LA, the employer did not ensure a portable band saw was on a stable platform while an employee was cutting concrete blocks on a wheel barrel.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  undefined :     On or about December 10, 2014, at 2226 Murphy Street, Shreveport, LA, the employer did not ensure that an electric cord on a lighting assembly being operated by an employee was not worn or frayed.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  On or about December 10, 2014, at 2226 Murphy Street, Shreveport, LA, the employer did not ensure that a portable masonry band saw in use by an employee had sufficient strain relief on a flexible cord exposing wires to the a/c receptacle plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0