Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARETEK INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CARETEK INC in 9911 E 47TH AVENUE, DENVER, CO 80238 (NAICS 323119). OSHA activity number 340160266.

Watch Caretek INC — free Get an email when a new federal OSHA severe-injury report for Caretek INC is published. One employer, no account, unsubscribe in one click.
Establishment
CARETEK INC
Site address
9911 E 47TH AVENUE
City
DENVER
State
CO
ZIP
80238
Mailing
9911 E 47TH AVENUE, DENVER, CO 80238
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323119
Employees
55
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    (a) Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to injurious light radiation.  Employees operated a Radian Laser System model 115-3AX Class IV carbon dioxide laser.  The interlock for the beam path enclosure for the Class IV CO2 laser had been overridden.  The Class IV laser was operated with the beam path not completely enclosed.  This condition exposed employees to a non-ionizing radiation hazard.    (b) Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to injurious light radiation.  Employees operated a Chinese Class IV Nd:YAG laser.  The beam path was not enclosed.  The beam was targeted at a reflective surface.  This condition exposed employees to a non-ionizing radiation hazard.    (c) Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to injurious light radiation.  Employees operated a Radian Laser System model 115-3AX Class IV carbon dioxide laser and a Chinese Class IV Nd:YAG laser.  Employees were not provided training with regards to the hazards of lasers and appropriate measures to protect themselves from exposure to hazardous light radiation.  This condition exposed employees to a non-ionizing radiation hazard.    Abatement Note:  Among other methods, feasible abatement methods include:  (1) Compliance with ANSI/LSI Z136.1 "American National Standard for Safe Use of Lasers", including but not limited to the following:    (a) Re-engage interlock on Radian Class IV CO2 laser beam path enclosure;    (b) Installation of beam path enclosure on Chinese Class IV Nd:YAG laser;    (c) Enclosure of open beam path of any other Class IV CO2 lasers;    (d) Calculate NHZ and ensure enclosure of beam path and removal of reflective surfaces for each laser;    (e) Assign Laser Safety Officer; and   (f) Provide laser safety training to operators.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.132 D01

Serious Gravity 1 1 instance 55 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a)Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).  Employees conducted operations which included exposure to hazardous nonionizing radiation and flying particles.  Hazardous operations included, but are not limited to the following:    1.  Exposure to Class IV carbon dioxide and Class IV Nd:YAG laser's non-ionizing radiation;   2.  Exposure to flying particles when processing printed or engraved materials; and  3.  Exposure to lacerations when handling rough surfaced materials.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.133 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   (a)Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards  from potentially injurious light radiation.  Employees operated a Radian Laser System model 115-3AX Class IV carbon dioxide and a Chinese Class IV Nd:YAG laser.  Protective eyewear for the appropriate wavelength and power of each laser was not available.  This condition exposed employees to a non-ionizing radiation hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 A

Other-than-serious 1 instance 55 exposed
Issued
Penalty
Initial $595.00 · Current $357.00 Reduced
29 CFR 1904.29(a): An OSHA 300 form or equivalent form was not used for recordable injuries and illnesses:    (a)Caretek Inc. dba Colorado Timberline at 9911 E 47th Avenue, Denver, CO: On and preceding 1/2/15, Caretek Inc did not use OSHA 300 forms or equivalent forms for recordable injuries and illnesses.  Employees sustained one, four, and two recordable injuries in 2014, 2013, and 2012 respectively.  The employer did not record the injuries in OSHA 300 logs or equivalent forms.
Recent events (2)
  • — I (O) $357
  • — Z (O) $595

View CARETEK INC's full OSHA safety record →