DOYLESTOWN, PA —
OSHA Inspection: EAST COAST CHEVY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST COAST CHEVY, INC. in 4154A SKYRON DRIVE, DOYLESTOWN, PA 18902 (NAICS 441310). OSHA activity number 340166495.
Where did this inspection happen?
- Establishment
- EAST COAST CHEVY, INC.
- Site address
- 4154A SKYRON DRIVE
- City
- DOYLESTOWN
- State
- PA
- ZIP
- 18902
- Mailing
- 4154A SKYRON DRIVE, DOYLESTOWN, PA 18902
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 14
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) Metal Fabrication Area - On or about January 7, 2015, a standard railing was not provided on the open sides of the second story parts storage area to prevent employees from falling to the lower level. b) Shipping Receiving Area - On or about January 7, 2015, a standard railing was not provided on the open sides of the second story loading area and box storage area to prevent employees from falling to the lower level.
Recent events (2)
- — I (S) $1800
- — Z (S) $2400
1910.24 H
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) Metal Fabrication Area - On or about January 7, 2015, the stairway leading to the mezzanine area was not provided with a standard guardrail on the open sides of the steps and does not extend to full length of stairway to the top riser. b) Shipping and Receiving Area - On or about January 7, 2015, the stairway leading to the mezzanine area was not provided with a standard guardrail on the open sides of the steps.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Shipping and Receiving - On or about January 7, 2015, a relocatable power tap is being used as an alternative to fixed wiring at work bench. b) Welding Shop - On or about January 7, 2015, a relocatable power tap is being used as a permanenent power source to power a grinder and other equipment. c) Mechanical Shop - On or about January 7, 2015, a relocatable power tap is being used as an alternative to fixed wiring.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Mechanical Shop - On or about January 7, 2015, the electrical cord used to power the portable shop light is not provided with a tension relief device which split the exterior insulation at the joint, exposing the internal wiring.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure a) Shipping / Receiving - On or about January 7, 2015, flexible cords attached to outlets at the overhead mezzanine were attached over the door frame and routed to a workbench at the lower level.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: a) Shipping and Receiving - On or about January 7, 2015, flexible cords attached to outlets at the overhead mezzanine were attached over the door frame and routed to a workbench at the lower level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Welding Shop - On or about January 7, 2015, the flexible wiring powering the Daytona Bench Grinder has damaged outer sheathing which has been improperly repaired and has not been taken out of service.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Worksite - On or about January 7, 2015, the employer did not develop a written Hazard Communication program for the chemicals used in the workplace.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: a) Mechanical Shop - On or about January 7, 2015, the employer did not provided Material Safety Data Sheets for the chemicals employees are using to clean engine parts. b) Welding Shop - On or about January 7, 2015, the employer did not provided with Material Safety Data Sheets for the employee who performs welding on sheet metal and uses other types of chemicals.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Shop wide - On or about January 7, 2015, the employer did not provide employees with training on the hazards of chemicals used in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) Shipping and Receiving Area - On or about January 7, 2015, the employer did not certify that each operator was evaluated prior to operating a forklift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 441310)
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
BARDSTOWN, KY—2026-07-15
69326 - TOWER AUTOMOTIVE OPERATIONS USA I LLC
BREA, CA—2026-07-15
WORLDPAC
PALM DESERT, CA—2026-07-10
AUTOZONE AUTO PARTS
CHELSEA, ME—2026-07-01
SOULE'S AUTO SUPPLY, INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340166495.