Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MELVIN PEREZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MELVIN PEREZ in 4812 CHENEVERT, HOUSTON, TX 77004 (NAICS 238130). OSHA activity number 340182930.

Watch Melvin Perez — free Get an email when a new federal OSHA severe-injury report for Melvin Perez is published. One employer, no account, unsubscribe in one click.
Establishment
MELVIN PEREZ
Site address
4812 CHENEVERT
City
HOUSTON
State
TX
ZIP
77004
Mailing
9445 CONCOURSE, HOUSTON, TX 77036
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation.      At south side of the structure; an employee worked from a pump jack scaffold platform that did not have mud sills, exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $1700

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level.            At south side of the structure; an employee worked from a pump jack scaffold that did not have a guardrail system, exposing employees to fall hazards at approximately 22 feet.
Recent events (1)
  • — Z (S) $2800

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace were not installed approximately 4 feet (1.2 m) above the brace to be passed, and were not left in place until the pump jack has been moved and the original brace reinstalled.           At south side of the structure; an employee worked from a pump jack scaffold that was not secured to the wall structure, exposing employees to fall hazards at approximately 22 feet.
Recent events (1)
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340182930.