Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CASSWAY CONTRACTING CORP

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of CASSWAY CONTRACTING CORP in 480 MAIN ST, ROOSEVELT ISLAND, NY 10044 (NAICS 238310). OSHA activity number 340183391.

Watch Cassway Contracting Corp — free Get an email when a new federal OSHA severe-injury report for Cassway Contracting Corp is published. One employer, no account, unsubscribe in one click.
Site address
480 MAIN ST
City
ROOSEVELT ISLAND
State
NY
ZIP
10044
Mailing
771 NEPPERHAN AVE., YONKERS, NY 10703
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
55
Ownership type
A

3 citations on file for this inspection.

1926.304 D

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4500.00 · Current $4500.00
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe:   a) 3N:  On or about January 15, 2015  An employee used a unguarded table saw to cut baseboards.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4500.00 · Current $3600.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    a) 17D Kitchen:    On or about January 15, 2015    An employee used a Hilti SD 4500 which was plugged in by extension cord.  The extension cord was not protected by GFI.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3600.00 · Current $0.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) 17F:    On or about January 15, 2015    An employee used a drywall screw-gun which was plugged in by extension cord.  The extension cord was missing the ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

View CASSWAY CONTRACTING CORP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183391.