Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LONGVIEW WASTE SYSTEMS CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LONGVIEW WASTE SYSTEMS CO. in 149 NICHOL AVENUE, MC KEES ROCKS, PA 15136 (NAICS 562998). OSHA activity number 340192988.

Watch Longview Waste Systems CO. — free Get an email when a new federal OSHA severe-injury report for Longview Waste Systems CO. is published. One employer, no account, unsubscribe in one click.
Site address
149 NICHOL AVENUE
City
MC KEES ROCKS
State
PA
ZIP
15136
Mailing
149 NICHOL AVENUE, MC KEES ROCKS, PA 15136
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562998
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $1200.00 · Current $780.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a) Jobsite, 149 Nichol Avenue, McKees Rocks, PA 15136:  Observed on or about December 22, 2014, compressed gas cylinders containing oxygen were stored directly next to a cylinder of acetylene.  Employees working in the shop area were exposed to a fire hazard due to the improper storage of oxygen and acetylene gas cylinders.
Recent events (2)
  • — I (S) $780
  • — Z (S) $1200

1910.305 G01 IV C

Serious Gravity 1 1 instance 7 exposed
Issued
Penalty
Initial $1200.00 · Current $780.00 Reduced
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and/or cables were run through doorways, windows, or similar openings:      a) Jobsite, 149 Nichol Avenue, McKees Rocks, PA 15136:  Observed on or about December 22, 2014, a flexible cord (110 Volt) used to power a fuel tank on the outside of the building was run through a doorway.  The cord was exposed to wear and tear from vehicles operating in the area.  Employees working in the main shop area were exposed to the hazard of electric shock.
Recent events (2)
  • — I (S) $780
  • — Z (S) $1200

1910.120 M

Other-than-serious 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.120(m):  While work was in progress, areas accessible to employees were lighted at less than the minimum illumination intensities listed in Table H-120.1:  a) Jobsite, 149 Nichol Avenue, McKees Rocks, PA 15136:  Observed on or about December 22, 2014, employees were not provided adequate lighting while working in the shop area due broken/inoperable overhead lights and broken lights on vehicles operating in the area.  Employees sorting materials in the shop area were exposed to tripping and struck-by hazards due to the lack of adequate lighting.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2):  The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:    a) Jobsite, 149 Nichol Avenue, McKees Rocks, PA 15136:  Observed on or about December 22, 2014, the employer did not verify, through a written certification, that a hazard assessment was completed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340192988.