PHILADELPHIA, MS —
OSHA Inspection: JERRY VOWELL LOGGING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JERRY VOWELL LOGGING in 17091 HIGHWAY 19 NORTH, PHILADELPHIA, MS 39350 (NAICS 113310). OSHA activity number 340195023.
Where did this inspection happen?
- Establishment
- JERRY VOWELL LOGGING
- Site address
- 17091 HIGHWAY 19 NORTH
- City
- PHILADELPHIA
- State
- MS
- ZIP
- 39350
- Mailing
- 17091 HIGHWAY 19 NORTH, PHILADELPHIA, MS 39350
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 113310
- Employees
- 24
- Ownership type
- A
Citations
16 citations on file for this inspection.
1910.23 A09
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1910.23(a)(9): Each floor hole, into which persons could not accidentally walk, was not protected by a cover that leaves no openings more than 1 inch wide: (a) Sawmill - On or about January 20, 2015, employees were exposed to a fall/trip hazard due to a hole on the logging deck platform that was 13.5 inches in width.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.23 E01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): The railing did not consist of top rail, intermediate rail, and posts, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level: (a) Sawmill - On or about January 20, 2015, the guard rail on the logging deck platform did not have a mid-rail as required.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4): (a) Sawmill - On or about January 20, 2015, employees were required to service and maintain equipment and the employer had not implemented an energy control program to prevent the accidental release of stored energy.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.212 A05
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch: (a) Maintenance Shop - On or about January 20, 2015, the blades on an overhead fan were not guarded as required.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour: (a) Maintenance Shop - On or about January 20, 2015, oxygen and acetylene cylinders were improperly stored together.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.265 C30 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.265(c)(30)(ii): Vehicle(s) were not equipped with audible warning signals: (a) Jobsite located on Highway 14 between Louisville and Kosciusko - On or about January 20, 2015, the backup alarm was not working on a Dozer and a Skidder.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.266 I07 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.266(i)(7)(i): The employer did not assure that each employee, including supervisors, had received first-aid and CPR training meeting at least the requirements specified in Appendix B: (a) Facility - On or about January 20, 2015, all employees performing logging operations were not trained in first aid and CPR as required by the standard.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.304 G05
- Issued
- Penalty
- Initial $1020.00 · Current $612.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) Mill Area - On or about January 20, 2015, the ground pin was missing from an electric power cord.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Mill Area - On or about January 20, 2015, an extension cord being used to service an oil cooling fan did not have strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Penalty
- Initial $1020.00 · Current $612.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: (a) Maintenance Shop - On or about January 20, 2015, unused openings in the electrical panel were not effectively closed as required.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.305 B02 I
- Issued
- Penalty
- Initial $1020.00 · Current $612.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Mill Office Area - On or about January 20, 2015, faceplates were missing from electrical outlets.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Facility - On or about January 20, 2015, employees were using chemicals including but not limited to oxygen, acetylene, diesel fuel, hydraulic oil, and gasoline and the employer had not implemented a hazard communication program.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not have a written certification of hazard assessment identifying the workplace evaluated; the person certifying that the evaluation has been performed; and the date(s) of the hazard assessment: (a) Facility - On or about January 20, 2015, the employer did not have documentation to certify a hazard assessment had been conducted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 F04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(f)(4): The employer shall verify that each affected employee has received and understood the required training through a written certification that contains the name of each employee trained, the date(s) of training, and that identifies the subject of the certification: (a) Facility - On or about January 20, 2015, the employer did not have documentation to certify employees had been trained in the use of personal protective equipment (ppe).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) Facility - On or about January 20, 2015, the employer had not conducted an annual maintenance check of the fire extinguishers.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.266 I10 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.266(i)(10)(i): The employer did not verify compliance with paragraph (i) of this section by preparing a written certification record containing the name or other identity of the employee trained, the date(s) of the training, and the signature: (a) Facility - On or about January 20, 2015, the employer did not have documentation to certify employees performing logging operations had been trained as required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 113310)
ARKADELPHIA, AR—2026-07-06
JUSTIN KIRKSEY LOGGING, INC.
SEDRO WOOLLEY, WA—2026-07-02
WA317991915 - JANICKI LOGGING & CONSTRUCTION COINC
SONOMA, CA—2026-07-02
CAMPBELL & SON FALLING LLC
FORT BRAGG, CA—2026-07-01
NORTHWESTERN TIMBER FALLING INC.
COTTAGE GROVE, OR—2026-06-26
317744633 - TIMBER HARVESTING INC
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340195023.