WASHINGTON, DC —
OSHA Inspection: KADY CONSTRUCTION GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KADY CONSTRUCTION GROUP, INC. in 2122-24 3RD STREET, NW, WASHINGTON, DC 20011 (NAICS 236117). OSHA activity number 340199231.
Where did this inspection happen?
- Establishment
- KADY CONSTRUCTION GROUP, INC.
- Site address
- 2122-24 3RD STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 9234 ANNAPOLIS ROAD, LANHAM, MD 20706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Job Site - Employees were not provided with hazard recognition in the avoidance of unsafe conditions as evidenced by hazards such as but not limited to; employees not using personal protective equipment, fire extinguishers not provided and damaged cord used to supply power, on or about 01/22/2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.95 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) Unit 2122, First Floor - A carpenter not wearing eye protection was observed nailing a wood framing material member using a Paslode pneumatic nail gun, on or about 01/22/2015. b) Unit 2124, Second Floor -A carpenter not wearing eye protection was observed nailing plywood to the deck using a Paslode pneumatic nail gun, on or about 01/22/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) First Floor, Unit 2124 - Carpenters not wearing head protection were observed standing below carpenters installing plywood decking, on or about 01/22/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.150 C01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) Job Site - A portable fire extinguisher was not provided where electric tools and gasoline powered equipment were in use, on or about 01/22/2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Second Floor, Unit 2122 - Carpenters observed installing plywood decking were exposed to an 18 ft. fall hazard, on or about 01/22/2015. b) Rear of Unit 2124 - Employees observed stepping onto the top of an 8 inch wide basement retaining wall to gain access to the first floor were exposed to a 9 ft. fall hazard, on or about 01/22/2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Job Site - Employees were not provided with training in the recognition of hazards associated with falling as evidenced by hazards such as but not limited to; employees exposed to a 9 ft. and 18 ft. fall hazard not using any type of fall protection, on or about 01/22/2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(1)(i): Flexible cords and cables were not suitable for conditions of use and location: a) Exterior Front Sidewalk - An extension cord used to supply power to a Nakita portable electric circular saw had worn electric tape covering the damaged outer insulation, 120 volt, 15 amp service, on or about 01/22/2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236117)
NEWPORT BEACH, CA—2026-07-16
TRADEMARK CONSTRUCTION COMPANY, INC.
DOWNINGTOWN, PA—2026-07-09
NVR, INC.
WINSTON SALEM, NC—2026-07-08
161508 - CLAYTON PROPERTIES GROUP, INC.
PUNTA GORDA, FL—2026-07-08
SAGE HOMES LLC
LAKE STEVENS, WA—2026-07-02
WA317991942 - SEKISUI HOUSE WASHINGTON INC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340199231.