WATERTOWN, CT —
OSHA Inspection: THE SIDING GUYS, LLP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE SIDING GUYS, LLP in LOT 6, BELLA VISTA DRIVE, WATERTOWN, CT 06795 (NAICS 238170). OSHA activity number 340211549.
Where did this inspection happen?
- Establishment
- THE SIDING GUYS, LLP
- Site address
- LOT 6, BELLA VISTA DRIVE
- City
- WATERTOWN
- State
- CT
- ZIP
- 06795
- Mailing
- 646 BURLINGTON AVENUE, BRISTOL, CT 06010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 01/23/2015 at the Lot #6 Bella Vista Construction Site, employees were working from a pump jack scaffold system whose poles did not bear on any base plates, mud sills, or any other adequate firm foundations.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.451 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: On or about 1/23/2015 at the Lot #6 Bella Vista Construction Project, employees were working from pump jack scaffold systems and the bottoms of the poles were not secured from displacement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement. On or about 1/23/2015 at the Lot #6 Bella Vista Construction Project, employees were working from pump jack scaffold systems and the footings were not level, sound, or rigid.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about 1/23/2015 at the Lot #6 Bella Vista Construction Project, employees were working from pump jack scaffold systems and the bottoms of the poles were not secured from displacement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340211549.