Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISIONED COMPONENTS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PRECISIONED COMPONENTS, LLC in 391 BARTON CHAPEL ROAD, APPLE GROVE, WV 25502 (NAICS 332999). OSHA activity number 340214741.

Watch Precisioned Components, LLC — free Get an email when a new federal OSHA severe-injury report for Precisioned Components, LLC is published. One employer, no account, unsubscribe in one click.
Site address
391 BARTON CHAPEL ROAD
City
APPLE GROVE
State
WV
ZIP
25502
Mailing
391 BARTON CHAPEL ROAD, APPLE GROVE, WV 25502
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
19
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1910.134(c)(1):  In any workplace where respirators were necessary to protect the health of the employee or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use:    (a)  Precisioned Components LLC:  The employer has not implemented a written respiratory protection program to protect employees from respiratory hazards such as but not limited to, respirable silica dust and metal dusts during abrasive blasting, as determined on January 28, 2015.    Abatement Certification Required for this Item.
Recent events (1)
  • — Z (S) $1200

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee(s) ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   (a) Abrasive Blasting Area:  The employer requires an employee to wear a Bullard supplied air respirator abrasive blasting helmet while conducting abrasive blasting.  The employer has not provided the employee with a medical evaluation to determine prior to required respirator use, as determined on January 28, 2015   Abatement Certification Required for this Item.
Recent events (1)
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  (a) Abrasive Blasting Area:  The employer requires an employee to wear a Bullard supplied air respirator abrasive blasting helmet while conducting abrasive blasting.  The employer has not provided the employee with training on the respirator and contents of the respiratory protection standard, as determined on January 28, 2015.   Abatement Certification Required for this Item.
Recent events (1)
  • — Z (S) $0

1910.134 I07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:  (a) Compressor Area:  An employee conducts abrasive blasting activities while required to wear a Bullard supplied air respirator abrasive blasting helmet. The breathing air is supplied by an Quincy QGD-25 oil lubricated compressor.  The Quincy compressor was not equipped with a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels, as determined on February 4, 2015.  Abatement Certification Required for this Item.
Recent events (1)
  • — Z (S) $2000

1910.134 I05 IV

Serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change of the sorbent bed and/or filters:  (a)  Abrasive Blasting Area:  An employee conducts abrasive blasting activities while required to wear a Bullard supplied air respirator abrasive blasting helmet.  The employer did not maintain a tag at the compressor filtering system showing the most recent change date and name of the person authorized to change sorbent bed and/or filters, as determined on February 4, 2015.  Abatement Certification Required for this Item.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340214741.