Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SEXTON LOGGING CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEXTON LOGGING CO., INC. in 10226 NORTHSIDE ROAD, NORTHPORT, AL 35475 (NAICS 113310). OSHA activity number 340221746.

Watch Sexton Logging CO., INC. — free Get an email when a new federal OSHA severe-injury report for Sexton Logging CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
10226 NORTHSIDE ROAD
City
NORTHPORT
State
AL
ZIP
35475
Mailing
10226 NORTHSIDE ROAD, NORTHPORT, AL 35475
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
113310
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1156.00 · Current $694.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:  (a) On or about 01/30/2015 - Maintenance shop area, CRAFTMAN bench mounted grinder, Serial number 0910-W, the work rest was adjusted to one inch of the wheel.
Recent events (2)
  • — I (S) $693.6
  • — Z (S) $1156

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  (a) On or about 01/30/2015 - Maintenance shop area, CRAFTMAN bench mounted grinder, Serial number 0910-W, the tongue guard was adjusted to one-half inch of the wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or about 01/30/2015 - Maintenance shop area, a 110-volt branch circuit receptacle was missing the faceplate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340221746.