Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALM ABATEMENTS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALM ABATEMENTS, LLC in 12707 E. MISSISSIPPI AVE. UNIT 209, AURORA, CO 80012 (NAICS 562910). OSHA activity number 340236892.

Watch ALM Abatements, LLC — free Get an email when a new federal OSHA severe-injury report for ALM Abatements, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALM ABATEMENTS, LLC
Site address
12707 E. MISSISSIPPI AVE. UNIT 209
City
AURORA
State
CO
ZIP
80012
Mailing
4720 S. SANTA FE CIRCLE #8, ENGLEWOOD, CO 80110
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.1101 F02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $750.00 Reduced
29 CFR 1926.1101(f)(2)(i):  The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation:          a)   On or about February 2, 2015, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while removing asbestos containing material (including surfacing material on drywall) because the employer had failed to perform an initial exposure assessment.
Recent events (2)
  • — I (S) $750
  • — Z (S) $1020

1926.1101 H03 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1101(h)(3)(iv)(A):  A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA):  a)  On or about February 2, 2015, and at times prior, the employer did not provide employees performing Class I asbestos abatement work with a full-face powered air-purifying respirator or a supplied air respirator.  Employees were performing removal of asbestos containing dry wall texturing with only half face air purifying respirators.  A negative exposure assessment had not been conducted for this project.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1101 G05 I B 2

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $750.00 Reduced
29 CFR 1926.1101(g)(5)(i)[B][2]:  Electrical circuits in the enclosure shall be deactivated, unless equipped with ground-fault circuit interrupters:      a)  On or about February 2, 2015, and at times prior, employees were exposed to electrical shock hazards while they worked inside an asbestos abatement enclosure in which all electrical circuits had not been deactivated or equipped with a ground-fault interrupter.  The wiring of the building (inside the walls) was not protected with ground-fault circuit interrupters.
Recent events (2)
  • — I (S) $750
  • — Z (S) $1020

1926.403 I02 I

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:  a)  Employees were exposed to electrical shock hazards because the employer did not ensure that the electrical outlets in the work area had covers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340236892.