BURLINGTON, NJ —
OSHA Inspection: ALVA-TECH, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ALVA-TECH, INC. in 1208 COLUMBUS ROAD, BURLINGTON, NJ 08016 (NAICS 423320). OSHA activity number 340408731.
Where did this inspection happen?
- Establishment
- ALVA-TECH, INC.
- Site address
- 1208 COLUMBUS ROAD
- City
- BURLINGTON
- State
- NJ
- ZIP
- 08016
- Mailing
- 1208 COLUMBUS ROAD, BURLINGTON, NJ 08016
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423320
- Employees
- 16
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Penalty
- Initial $1020.00 · Current $510.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Facility - South End- A 4 inch X 4 inch metal receptacle was used as an extension cord, on or about 2/18/15.
Recent events (2)
- — I (S) $510
- — Z (S) $1020
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Facility (South End) - The cord that was connected to the 4 X 4 metal receptacle had damaged strain relief, on or about 2/18/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Facility: The employer did not provide the information in the Appendix D to 29 CFR 1910.134 to employees who voluntary wore respirators such as but not limited to 3M Particulate Respirators model #8577, on or about 2/18/15. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ALVA-TECH, INC.
BURLINGTON, NJ—2016-07-07 00:00:00
ALVA-TECH, INC.
View ALVA-TECH, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423320)
GIBSONIA, PA—2026-06-30
FORM TECH CONCRETE FORMS
BLOOMSDALE, MO—2026-06-25
RICHARDS BRICK COMPANY
SAN JOSE, CA—2026-06-24
STONEVILLE USA, INC.
GRANDVIEW, WA—2026-06-18
WA317991864 - WESTERN MATERIALS INC
MACOMB, MI—2026-06-16
GRANITE & MARBLE DEPOT, INC
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340408731.