Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KDK ENTERPRISES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KDK ENTERPRISES, LLC in 317 INDUSTRIAL DR., JUNCTION, TX 76849 (NAICS 332999). OSHA activity number 340415173.

Watch KDK Enterprises, LLC — free Get an email when a new federal OSHA severe-injury report for KDK Enterprises, LLC is published. One employer, no account, unsubscribe in one click.
Site address
317 INDUSTRIAL DR.
City
JUNCTION
State
TX
ZIP
76849
Mailing
P.O. BOX 444, JUNCTION, TX 76849
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
11
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $435.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard:  Outside near the dumpster:      On or about February 09, 2015, an employee was exposed to a struck-by hazard, while operating a Mitsubishi Caterpillar Forklift, Model # FG30N, while not utilizing/wearing the required seatbelt.  The forklift was equipped with Roll Over Protection.
Recent events (2)
  • — I (S) $435
  • — Z (S) $1600

1910.134 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $435.00 Reduced
29 CFR 1910.134(c)(1):  A written respiratory protection program that included the provisions in 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    Sandblasting room:  On or about February 09, 2015, an employee was exposed to an inhalation hazard, while wearing a Supplied-air respirator (SAR) and sandblasting parts in preparation for finish coats, while the employer did not have a written respirator protection program.
Recent events (2)
  • — I (S) $435
  • — Z (S) $1600

1910.134 I01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $435.00 Reduced
29 CFR 1910.134(i)(1)(ii):  Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:    Sandblasting room:  On or about February 09, 2015, an employee was exposed to an inhalation hazard, while wearing a Supplied-air respirator (SAR) and sandblasting parts in preparation for finish coats, while the employer failed to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators.
Recent events (2)
  • — I (S) $435
  • — Z (S) $1600

1910.178 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $435.00 Reduced
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:     Outside near the dumpster:  On or about February 09, 2015, an employee was exposed to a struck-by hazard, while operating a Mitsubishi Caterpillar Forklift, Model # FG30N, while one of the tines had a 1" hole drilled through it near the tip, this hole was used for rigging and lifting material, without having this modification approved by the manufacturer.
Recent events (2)
  • — I (S) $435
  • — Z (S) $1600

1910.178 L01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(1)(ii):  The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:  Outside near the dumpster:  On or about February 09, 2015, an employee was exposed to a struck-by hazard, while operating a Mitsubishi Caterpillar Forklift, Model # FG30N, while not being trained and certified by his current employer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $435.00 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):       a)  Main production shop:  On or about February 09, 2015, an employee was exposed to a stuck-by hazard, while operating a Dewalt D28114 Angle Grinder and grinding metal parts, while the abrasive stone wheel was installed without a safety guard surrounding the wheel's periphery and sides.     b)  Main production shop:  On or about February 09, 2015, an employee was exposed to a stuck-by hazard, while operating a Dewalt DWE4011 Angle Grinder and grinding metal parts, while the abrasive stone wheel was installed without a safety guard surrounding the wheel's periphery and sides.     c)  Main production shop:  On or about February 09, 2015, an employee was exposed to a stuck-by hazard, while operating a Dewalt DWE4011 Angle Grinder and grinding metal parts, while the abrasive flap disc wheel was installed without a safety guard surrounding the wheel's periphery and sides.
Recent events (2)
  • — I (S) $435
  • — Z (S) $1600

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $425.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:      a)  At the yellow stationary metal chop saw:  On or about February 09, 2015, an employee was exposed to an electrical hazard, while operating a Kalamazoo Chop Saw, while the saws 240 Vac electrical line cable armor was not connect and thus not providing strain relief.    b)  At the beige, portable air compressor:  On or about February 09, 2015, an employee was exposed to an electrical hazard, while turning on/off the portable air compressor, while the compressors 230 Vac flexible power cord lacked a connector at the on/off switch thus not providing strain relief.
Recent events (2)
  • — I (S) $425
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340415173.