MEMPHIS, TN —
OSHA Inspection: HELM FERTILIZER TERMINAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HELM FERTILIZER TERMINAL, INC. in 1421 CHANNEL AVENUE, MEMPHIS, TN 38113 (NAICS 424910). OSHA activity number 340425305.
Where did this inspection happen?
- Establishment
- HELM FERTILIZER TERMINAL, INC.
- Site address
- 1421 CHANNEL AVENUE
- City
- MEMPHIS
- State
- TN
- ZIP
- 38113
- Mailing
- P.O. BOX 13404, MEMPHIS, TN 38113
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424910
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1918.62 A02
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1918.62(a)(2): Defective gear, as defined by the manufacturer's specifications, was used by the employer. a) Dry Dock - On or about 2/24/15, employees were exposed to struck-by hazards when hooks on lifting bridles were not equipped with safety latches. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1020
- — Z (S) $1700
1918.64 L03
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1918.64(l)(3): Conveyors were not operated with all the overload devices, guards, and/or safety devices in place and operable. a) Dry Dock - On or at 2/24/15, employees were exposed to amputation hazards when a belt and pulley was not guarded on the barge end hopper. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1020
- — Z (S) $1700
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Liquid Dock - On or about 2/24/15, strain relief was not provided on the power cord for the hoist. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J02 V
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered a) Liquid Dock - On or about 2/24/15, employees were exposed to electrical hazards when an outside outlet was not protected against water accumulation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1918.97 D07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1918.97(d)(7): Stretchers in permanent locations were not mounted to prevent damage or be protected from the elements if located out-of-doors. a) Dry Dock - On or about 2/24/15, the stretcher/stokes basket was not protected from the weather. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1918.97 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1918.97(e)(1): The employer did not ensure that there was in the vicinity of each vessel being worked, at least one U.S. Coast Guard approved 30-inch life-ring with no less than 90 feet of line attached, and at least one portable or permanent ladder that reaches from the top of the apron to the surface of the water. a) Dry Dock - On or about 2/24/15, a U.S. Coast guard approved life ring was not available. b) Liquid Dock - On or about 2/24/15, 90 feet of line was not attached to the life ring. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at HELM FERTILIZER TERMINAL, INC.
MEMPHIS, TN—2023-06-12 00:00:00
HELM FERTILIZER TERMINAL, INC.
MEMPHIS, TN—2015-02-24 00:00:00
HELM FERTILIZER TERMINAL, INC.
MEMPHIS, TN—2004-01-13 00:00:00
HELM FERTILIZER TERMINAL, INC.
MEMPHIS, TN—2003-10-02 00:00:00
HELM FERTILIZER TERMINAL, INC.
MEMPHIS, TN—1993-07-15 00:00:00
HELM FERTILIZER TERMINAL INC
View HELM FERTILIZER TERMINAL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424910)
MOSES LAKE, WA—2026-07-14
WA317991748 - J R SIMPLOT COMPANY LLC
MINNEAPOLIS, MN—2026-07-06
111527 - TWIN CITY SEED COMPANY
MERCED, CA—2026-07-02
NUTRIENT AG SOLUTIONS
ROARING RIVER, NC—2026-06-24
161413 - MCKINLEY PIERCE
EUGENE, OR—2026-06-16
317744539 - COASTAL FARM & HOME SUPPLY LLC
More inspections in TN
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
FAIRVIEW, TN—2026-07-16
DRB GROUP TENNESSEE, LLC
COVINGTON, TN—2026-07-16
CHARMS, LLC
MURFREESBORO, TN—2026-07-16
EUROSTONE LLC
MOUNT JULIET, TN—2026-07-15
SCHNEIDER ELECTRIC USA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340425305.