OSHA Inspection: KEESEE MOTOR COMPANY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KEESEE MOTOR COMPANY in 111 SOUTH BROADWAY, CORTEZ, CO 81321 (NAICS 441110). OSHA activity number 340434984.

Watch Keesee Motor Company — free Get an email when a new federal OSHA severe-injury report for Keesee Motor Company is published. One employer, no account, unsubscribe in one click.
Site address
111 SOUTH BROADWAY
City
CORTEZ
State
CO
ZIP
81321
Mailing
111 SOUTH BROADWAY, CORTEZ, CO 81321
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
41
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $3500.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards associated with improper automobile lift operations:   a) On or about February 26, 2015 and times prior, employees were exposed to crushing, struck-by, and amputation hazards while working around automotive lifts as follows:         1) Lifts were not inspected daily during use to ensure that they were properly maintained and functional.       2) Lifts were not lowered onto the safety locks while vehicles were being serviced. The safety locks on lifts #6 and #9 were not functioning as designed.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $3500

1910.147 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) On or about February 26, 2015 and times prior, employees were exposed to injuries from struck-by hazards when working on automotive lift #6 that had not been lockout prior to working on it.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $2100

1910.107 B05 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $700.00 · Current $700.00
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  a) On or about February 26, 2015 and times prior, the employer had not installed an approved automatic sprinkler system in the spray booth.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $700

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $700.00 · Current $700.00
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  On or about February 26, 2015 and times prior, the employer did not establish a written respiratory protection program and provide effective training to employees who used respirators to protect themselves from respirable dust and methyl ethyl ketone.  Employees used elastomeric half-face respirators and supplied air respirators without being provided medical evaluations and basic training which ensured that the use of the respirators themselves did not present a health hazard to the employees.    Abatement Note:  Fit testing shall follow the requirements listed in 29 CFR 1910.134(f).     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $700

1910.253 B04 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  a)  On or about February 26, 2015 and times prior, the employer was storing two of their oxygen cylinders next to one of their acetylene cylinders located next to the bay door.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   a) On or about February 26, 2015 and times prior, employees were exposed to injuries such as but not limited to electrical hazards at the following locations:      1) A 110 volt electrical box was missing a knockout that was located on the north wall of the body shop.      2) A 110 volt electrical box was missing a knockout that was located on the east outer wall of the paint booth.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $0

1910.305 G02 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a)  On or about February 26, 2015 and times prior, the employer did not remove from service a 110 volt flexible cord that had been spiced in several places.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").