Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SONRISE ENTERPRISE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SONRISE ENTERPRISE in 220 BRICKYARD ROAD, INDIANOLA, MS 38751 (NAICS 238910). OSHA activity number 340435494.

Watch Sonrise Enterprise — free Get an email when a new federal OSHA severe-injury report for Sonrise Enterprise is published. One employer, no account, unsubscribe in one click.
Establishment
SONRISE ENTERPRISE
Site address
220 BRICKYARD ROAD
City
INDIANOLA
State
MS
ZIP
38751
Mailing
220 BRICKYARD ROAD, INDIANOLA, MS 38751
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
7
Ownership type
A

21 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1):  The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to crushing and or struck by hazard from forklift tip over.  (a)  Work Area - On or about March 2, 2015 the  Clark -C25A, Hyster 0046 and TCM FHD 36 industrial truck that were not equipped with seat belts.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.178 P01

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)  (a) Work Area - On or about March 2, 2015 the  Komatsu FG255, Clark - C25A, Hyster 0046 and TCM FHD 36 forklifts lacked operable horns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  (a) Bathroom - On or about March 2, 2015 the toilet in the employee bathroom was un-sanitized and the floor contained an accumulation of debris and water.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.141 D02 II

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:  (a) Bathroom - On or about March 2, 2015 the bathroom did not have hot or tepid running water.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.141 D02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent:   (a) Bathroom - On or about March 3, 2015 the bathroom was not equipped with hand soap or a cleansing agent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 D02 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:  (a) Bathroom: On or about March 2, 2015 there were no hand towels or air blower in the bathroom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s)  (a) Woodworking Area, East End - On or about March 2, 2015 the Dewalt Miter Saw lacked a guard thereby exposing employees to the hazard of coming in contact with the blade.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  (a) East end of the wood working area - On or about March 2, 2015, the Jet table saw was not guarded by an automatic adjusting hood exposing employees to the hazard of coming in contact with the blade.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) West end of Wood Working Area - On or about March 2, 2015 the Delta bench grinder had a work rest that was set at one half of an inch from the abrasive wheel.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  (a) West end of the wood working area: On or about March 2, 2015 the Delta Bench grinder lacked adjustable tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling  a.  Break room/Bathroom - On or about March 2, 2015, a flexible cord providing power to the lights and fan was attached to unapproved duplex receptacle.  The ground wire was not connect and the cord did not allow for strain relief.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 A02 X

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.305(a)(2)(x): 29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:  (a) West wall - On or about March 2, 2015,  Main electrical power cable supplying electricity to the building ran under the metal siding of an outer wall.  The outer sheating had been cut by the metal.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 B01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:(a)   a.  Break room/bathroom - On or about March 2, 2015, Conductors entering the electrical box for the compressor was not protected from abrasion exposing employees to the hazard of contacting an energized source.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  (a) Break room/Bathroom - On or about March 2, 2015 the electrical circuit box for the compressor located on the east wall had unused opening on top of the box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy  (a) Break room/ Bathroom - On or about March 2, 2015,  three duplex receptacles on the east wall near the compressor lacked faceplates/covers exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Wood Working Area - On or about March 2, 2015 the employer has not established or implemented a written Hazard Communication Program.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 G01 IV A

Other-than-serious 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Bathroom - On or about March 2, 2015 an extension cord was used to supply power instead of fix wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  (a) Wood Working Area - On or about March 2, 2015 extension cords had been spliced together.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F05 I

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  (a) Wood Working Area - On or about March 2, 2013 100 gallon tank of spent engine oil and cut off 55 gallon barrel  of hydraulic fluid lacked a label with the identity of the chemical contained.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F05 II

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a) Wood Working Area - On or about March 2, 2015 100 gallon tank of spent engine oil and cut off 55 gallon barrel  of hydraulic fluid lacked a label with the appropriate hazard warning.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G10

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(10): The employer did not ensure that, in all cases, the required information was provided for each hazardous chemical, and was readily accessible during each work shift to employees when they were in their work area(s):  (a) Wood Working Area - On or about March 2, 2015 the material safety sheets were not available to the employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340435494.