CAPE CORAL, FL —
OSHA Inspection: DESTINO CARPENTRY, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DESTINO CARPENTRY, LLC. in 2552 LAURENTINA LN, CAPE CORAL, FL 33909 (NAICS 236115). OSHA activity number 340446343.
Where did this inspection happen?
- Establishment
- DESTINO CARPENTRY, LLC.
- Site address
- 2552 LAURENTINA LN
- City
- CAPE CORAL
- State
- FL
- ZIP
- 33909
- Mailing
- 2806 35TH STREET SW, LEHIGH ACRES, FL 33976
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $1360.00 · Current $1360.00
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about 3/6/2015, employees were exposed to a struck-by hazard by not wearing safety glasses while operating pneumatic nail guns.
Recent events (1)
- — Z (S) $1360
1926.501 B13
- Issued
- Penalty
- Initial $2040.00 · Current $2040.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 3/6/2015, employees was exposed to the hazard of falling approximately 10 feet, while installing fascia boards on a residential property that was under construction, without being protected from falling.
Recent events (1)
- — Z (S) $2040
1926.1053 B01
- Issued
- Penalty
- Initial $2040.00 · Current $2040.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about 3/6/2015, employees was exposed to the hazard of falling approximately 10 feet while using a portable extension ladder, that did not extend 3 feet past the landing surface, to gain access to the roof trusses on a residential property that was under construction.
Recent events (1)
- — Z (S) $2040
More inspections in this industry (NAICS 236115)
CARSON CITY, NV—2026-07-16
LT BUILDERS
FAIRVIEW, TN—2026-07-16
DRB GROUP TENNESSEE, LLC
DOVER, NH—2026-07-15
KNOX MARSH DEVELOPMENT LLC
VIENNA, VA—2026-07-15
OMARI CONSTRUCTION LLC
NORFOLK, VA—2026-07-15
SUPERIOR PRIDE INC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340446343.