OSHA Inspection: THERMAL PLASTIC DESIGN, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERMAL PLASTIC DESIGN, INC in 1116 EAST PINE STREET, SAINT CROIX FALLS, WI 54024 (NAICS 326199). OSHA activity number 340456532.

Watch Thermal Plastic Design, INC — free Get an email when a new federal OSHA severe-injury report for Thermal Plastic Design, INC is published. One employer, no account, unsubscribe in one click.
Site address
1116 EAST PINE STREET
City
SAINT CROIX FALLS
State
WI
ZIP
54024
Mailing
1116 EAST PINE STREET, SAINT CROIX FALLS, WI 54024
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
46
Ownership type
A

5 citations on file for this inspection.

1910.37 B05

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1470.00 Reduced
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    (a) Warehouse area; The door in back of warehouse area was not appropriately marked "Not an Exit".
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.147 D03

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $1470.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    (a) Manufacturing area; All energy isolating devices on Cincinnati molding machine's were not identified or operated in a manner to prevent the machine from being energized during mold changes.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $4900

1910.147 D04 II

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position:    (a) Manufacturing area; Lock out devices were not affixed to the Cincinnati molding machines at the main electrical power source during mold changes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1470.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) Tool room area; The Fadal mill, machine #10, was not properly guarded to prevent the operator from coming into contact with point of operation during operation.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $3500

1910.219 C02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    (a) Tool room area; The Chavaller grinder, machine #3, had an unguarded horizontal rotating shaft less the seven feet from the floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340456532.