SAINT CROIX FALLS, WI —
OSHA Inspection: THERMAL PLASTIC DESIGN, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THERMAL PLASTIC DESIGN, INC in 1116 EAST PINE STREET, SAINT CROIX FALLS, WI 54024 (NAICS 326199). OSHA activity number 340456532.
Where did this inspection happen?
- Establishment
- THERMAL PLASTIC DESIGN, INC
- Site address
- 1116 EAST PINE STREET
- City
- SAINT CROIX FALLS
- State
- WI
- ZIP
- 54024
- Mailing
- 1116 EAST PINE STREET, SAINT CROIX FALLS, WI 54024
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 46
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 B05
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $1470.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): (a) Warehouse area; The door in back of warehouse area was not appropriately marked "Not an Exit".
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $1470.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: (a) Manufacturing area; All energy isolating devices on Cincinnati molding machine's were not identified or operated in a manner to prevent the machine from being energized during mold changes.
Recent events (2)
- — I (S) $1470
- — Z (S) $4900
1910.147 D04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position: (a) Manufacturing area; Lock out devices were not affixed to the Cincinnati molding machines at the main electrical power source during mold changes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1470.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Tool room area; The Fadal mill, machine #10, was not properly guarded to prevent the operator from coming into contact with point of operation during operation.
Recent events (2)
- — I (S) $1470
- — Z (S) $3500
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Tool room area; The Chavaller grinder, machine #3, had an unguarded horizontal rotating shaft less the seven feet from the floor.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340456532.