Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CESAR NAVA ARELLANO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CESAR NAVA ARELLANO in 1723 WHITFIELD PARC CIRCLE, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 340456847.

Watch Cesar Nava Arellano — free Get an email when a new federal OSHA severe-injury report for Cesar Nava Arellano is published. One employer, no account, unsubscribe in one click.
Establishment
CESAR NAVA ARELLANO
Site address
1723 WHITFIELD PARC CIRCLE
City
SMYRNA
State
GA
ZIP
30080
Mailing
1150 ATANTA RD SE LOT 615, MARIETTA, GA 30060
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.102(a)(1): Eye protective equipment was not provided or used when machines or operations presented potential eye injury from physical agents.  (a) 1704 Whitfield Parc Circle, Smyrna, GA: The employer exposed employees to eye injuries while operating pneumatic nail guns, in that; no protective eyewear was provided or in use while operating the nail guns.
Recent events (1)
  • — Z (S) $1600

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) 1704 Whitfield Parc Circle, Smyrna, GA: The employer exposed employees to electrical shock hazards, in that; the power cord of the air compressor did not have a ground pin installed.
Recent events (1)
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) 1704 Whitfield Parc Circle, Smyrna, GA: The employer exposed employees to lower level fall hazards of approximately 11-feet, in that; no approved means of fall protection was in use.
Recent events (1)
  • — Z (S) $2800

1926.405 G02 IV

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) 1704 Whitfield Parc Circle, Smyrna, GA: The employer exposed employees to electrical shock hazards, in that; the electrical cord of the air compressor's on/off controller did not have adequate strain relief.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340456847.