Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: WHATEVER IT TAKES TRANSMISSION PARTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WHATEVER IT TAKES TRANSMISSION PARTS, INC. in 618 SOUTH GALLATIN STREET, JACKSON, MS 39204 (NAICS 423120). OSHA activity number 340457365.

Watch Whatever IT Takes Transmission Parts, INC. — free Get an email when a new federal OSHA severe-injury report for Whatever IT Takes Transmission Parts, INC. is published. One employer, no account, unsubscribe in one click.
Site address
618 SOUTH GALLATIN STREET
City
JACKSON
State
MS
ZIP
39204
Mailing
618 SOUTH GALLATIN STREET, JACKSON, MS 39204
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423120
Employees
5
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2380.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1):  The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to: being crushed due to the absence of a permanently attached seat, seatbelts and an operational horn on the Toyota FGC15 powered industrial truck.    (a) In and around the Whatever It Takes Transmission Parts, Inc. warehouse - On or about March 11, 2015, employees operating the 1971 model Toyota powered industrial truck were exposed to injury due to the absence of a permanently attached seat, seatbelts, and an operational horn on the Toyota FGC15 powered industrial truck.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $4250

1910.303 G02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1410.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:    (a) North side of the East roll-up door - On or about March 11, 2015, employees were exposed to contact with live electrical parts due to the right half of an energized, horizontally-mounted duplex receptacle having been damaged.
Recent events (2)
  • — I (S) $1410
  • — Z (S) $2550

1910.304 G06 VI C 1

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $2550.00 · Current $1410.00 Reduced
29 CFR 1910.304(g)(6)(vi)(C)(1): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment, such as refrigerators. freezers. and air conditioners were not grounded:      (a) South wall, near the southeast corner of the Warehouse - On or about March 11, 2015, employees were exposed to electrical shock due to the Hotpoint Refrigerator not being grounded because it was connected to power from an SJTW, 3-wire AWG-16-3 extension cord which was missing its grounding prong.
Recent events (2)
  • — I (S) $1410
  • — Z (S) $2550

1910.22 A02

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition. Where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided where practicable.  (a)  Throughout the Whatever It Takes Transmission Parts, Inc. warehouse - On or about March 11, 2015, employees were exposed to standing puddles of dripping rain water on floors, at the West end of parts racks #A - #K, due to multiple roof/ceiling leaks.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 B01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.  (a) Near west end of Storage Rack "C" - On of about March 11, 2015, employees walking/working in the aisle between Racks "C & D" were exposed to a tripping hazard created by an old hydraulic lift channel bolted to the floor plate (6 1/2" wide X 2 1/2" high X 39 1/2" long) which jutted out halfway across the aisle.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) South wall, behind and near west end of Parts Rack "A" - On or about March 11, 2015, employees were exposed to not being able to utilize a General 2 1/4 lb. Dry Chemical Fire Extinguisher due to it being inaccessible on the wall, behind Parts Rack "A."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) Throughout the warehouse - On or about March 11, 2015 employees were exposed to minor burns due to the employer's failure to perform annual inspections on five (5) Type A:B:C fire extinguishers.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) Outside East Wall of Break Room and opposite west end of parts racks - On or about March 11, 2015 employees were exposed to minor injury due to the absence of circuit identification labeling for all ten (10) circuit-breakers inside the 100 Amp Siemens Indoor Load Center.  (b) Southeast Corner of Warehouse - On or about March 11, 2015, employee(s) were exposed to injury due to the absence of circuit identification labeling for three (3) circuit-breakers inside the Federal Pacific Electric Products disconnect panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  (a) Outside East Wall of Break Room and opposite west end of parts racks - On or about March 11, 2015 employees were exposed to minor burns due to any access to the 100 Amp Siemens Indoor Load Center being blocked by a pile of white, empty, cardboard parts boxes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Throughout the Warehouse - On or about March 11, 2015, employees were exposed to injury due to the use of flexible extension cords as substitutes for fixed wiring, to wit:     (1) to power the Coca Cola Machine adjacent the East roll-up door,      (2) to power lighting above the parts counter, and      (3) to power ceiling fluorescent lighting, etc. from a multi-tap outlet strip outside the SE corner of the storage room.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View WHATEVER IT TAKES TRANSMISSION PARTS, INC.'s full OSHA safety record →