Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEPARTMENT OF ARMY, YAKIMA TRAINING CENTER BULK FUEL POINT

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEPARTMENT OF ARMY, YAKIMA TRAINING CENTER BULK FUEL POINT in 970 FIRING CENTER RD, BULK FUEL POINT, YAKIMA, WA 98901 (NAICS 921190). OSHA activity number 340478676.

Watch Department OF Army, Yakima Training Center Bulk Fuel Point — free Get an email when a new federal OSHA severe-injury report for Department OF Army, Yakima Training Center Bulk Fuel Point is published. One employer, no account, unsubscribe in one click.
Site address
970 FIRING CENTER RD, BULK FUEL POINT
City
YAKIMA
State
WA
ZIP
98901
Mailing
970 FIRING CENTER RD, BUILDING 140, YAKIMA, WA 98901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921190
Employees
1
Ownership type
D

2 citations on file for this inspection.

1910.24 F

Serious Gravity 1 4 instances 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:  a) Fuel Bulk Point, where the rise height of the foundation structure to the stairs was not uniform:  1. Tank 1, where the concrete cover for the stilling tank measured 24 inches above ground level.  2. Tank 1, where the rise between the concrete cover for the stilling tank and the metal stairway measured 13 inches.   3. Tank 2, where the concrete cover for the stilling tank measured 18 inches above ground level.  4. Tank 2, where the rise between the concrete cover for the stilling tank and the metal stairway measured 13 inches.
Recent events (1)
  • — Z (S) $0

1910.24 G

Serious Gravity 5 3 instances 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(g): 29 CFR 1910.24(g): Stairway platforms were not at least the width of the stairway and 30 inches in length measured in the direction of travel:   a) Fuel Bulk Point, where stairway platforms measuring less than 24 inches included:  1. Tank 1, where the width of the platform ranged from 15 ¾ to 16 inches due to the placement of the high level alarm canister.  2. Tank 2, where the width of the platform ranged from 14 to 18 inches due to the placement of the high level alarm canister.   3. Tank 3, where the width of the platform ranged from 15 3/4 to 16 inches due to the placement of the high level alarm canister.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340478676.