MIDDLETOWN, NY —
OSHA Inspection: MICHEAL CONSTRUCTION, LLC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MICHEAL CONSTRUCTION, LLC. in 31 SCHUTT RD., MIDDLETOWN, NY 10940 (NAICS 238160). OSHA activity number 340480656.
Where did this inspection happen?
- Establishment
- MICHEAL CONSTRUCTION, LLC.
- Site address
- 31 SCHUTT RD.
- City
- MIDDLETOWN
- State
- NY
- ZIP
- 10940
- Mailing
- 385 RIDGE ST., NEWARK, NJ 07104
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.25 A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) On or about March 20, 2015 and at times prior thereto at the jobsite; there was a large amount of insulation, scrap wood, wood planks with nails protruding, and nails throughout the worksite where employees were working and walking.
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 20, 2015 and at times prior thereto at the jobsite; roofers were installing sheeting to the second floor roof while not being tied off to the rope grab system that was in place.
Recent events (1)
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about March 20, 2015 and at times prior thereto at the jobsite; employees exposed to fall hazards from the second story roof were not given training on how to recognize and adequately protect themselves from potential falls.
Recent events (1)
- — Z (S) $1200
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about March 20, 2015 and at times prior thereto at the jobsite; the ladder employees used to access the roof extended only 2 feet from the landing surface.
Recent events (1)
- — Z (S) $1600
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about March 20, 2015 and at times prior thereto at the jobsite; employees used one piece of an extension ladder to access the first floor from the ground level. The ladder was designed to be used with its 2 pieces connected as one. b) On or about March 20, 2015 and at times prior thereto at the jobsite; employees used a closed a-frame ladder on its side to access the first floor from the ground level. The ladder was designed to be used in its open position.
Recent events (1)
- — Z (S) $0
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) On or about March 20, 2015 and at times prior thereto at the jobsite; employees were using a ladder with a missing foot to access the second floor .
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340480656.