Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MICHEAL CONSTRUCTION, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MICHEAL CONSTRUCTION, LLC. in 31 SCHUTT RD., MIDDLETOWN, NY 10940 (NAICS 238160). OSHA activity number 340480656.

Watch Micheal Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for Micheal Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
31 SCHUTT RD.
City
MIDDLETOWN
State
NY
ZIP
10940
Mailing
385 RIDGE ST., NEWARK, NJ 07104
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.25 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:   a)  On or about March 20, 2015 and at times prior thereto at the jobsite; there was a large amount of insulation, scrap wood, wood planks with nails protruding, and nails throughout the worksite where employees were working and walking.
Recent events (1)
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a)  On or about March 20, 2015 and at times prior thereto at the jobsite; roofers were installing sheeting to the second floor roof while not being tied off to the rope grab system that was in place.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a) On or about March 20, 2015 and at times prior thereto at the jobsite; employees exposed to fall hazards from the second story roof were not given training on how to recognize and adequately protect themselves from potential falls.
Recent events (1)
  • — Z (S) $1200

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a)  On or about March 20, 2015 and at times prior thereto at the jobsite; the ladder employees used to access the roof extended only 2 feet from the landing surface.
Recent events (1)
  • — Z (S) $1600

1926.1053 B04

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   a) On or about March 20, 2015 and at times prior thereto at the jobsite; employees used one piece of an extension ladder to access the first floor from the ground level.  The ladder was designed to be used with its 2 pieces connected as one.   b) On or about March 20, 2015 and at times prior thereto at the jobsite; employees used a closed a-frame ladder on its side to access the first floor from the ground level.  The ladder was designed to be used in its open position.
Recent events (1)
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:   a)  On or about March 20, 2015 and at times prior thereto at the jobsite; employees were using a ladder with a missing foot to access the second floor .
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340480656.