ARLINGTON, TX —
OSHA Inspection: FLEX-N-GATE, TEXAS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FLEX-N-GATE, TEXAS, LLC in 2400 CENTENNIAL DRIVE, ARLINGTON, TX 76011 (NAICS 441310). OSHA activity number 340482678.
Where did this inspection happen?
- Establishment
- FLEX-N-GATE, TEXAS, LLC
- Site address
- 2400 CENTENNIAL DRIVE
- City
- ARLINGTON
- State
- TX
- ZIP
- 76011
- Mailing
- 2400 CENTENNIAL DRIVE, ARLINGTON, TX 76011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 148
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1620.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) At the establishment; in the shipping/receiving area, employees operated the Toyota 5000 pound forklift, model BFGAFGU32, with the left rear tire badly torn and needing replaced or repaired, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $2160.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: At the establishment, in the rear bumper line, the power cord powering the Maxess floor fan had the ground prong missing, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $2160
- — Z (S) $3600
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1620.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: At the establishment, a hazard communication program was not developed or maintained when employees were using chemicals such as but not limited to, 3M Finesse-It Polish, exposing employees to the hazard of skin irritations.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
More inspections at FLEX-N-GATE, TEXAS, LLC
GRAND PRAIRIE, TX—2024-01-29 00:00:00
FLEX-N-GATE TEXAS, LLC
View FLEX-N-GATE, TEXAS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 441310)
PALM DESERT, CA—2026-07-10
AUTOZONE AUTO PARTS
CHELSEA, ME—2026-07-01
SOULE'S AUTO SUPPLY, INC.
ETOWAH, TN—2026-06-24
AUTOZONE STORES LLC
CAROLINA, PR—2026-06-24
WESTERN AUTO OF PUERTO RICO INC
SAN JUAN, PR—2026-06-18
AUTOZONE PUERTO RICO INC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source