On , OSHA opened a planned health inspection of FLEX-N-GATE, TEXAS, LLC in 2400 CENTENNIAL DRIVE, ARLINGTON, TX 76011 (NAICS 441310). OSHA activity number 340482678.

Watch Flex-N-Gate, Texas, LLC — free Get an email when a new federal OSHA severe-injury report for Flex-N-Gate, Texas, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2400 CENTENNIAL DRIVE
City
ARLINGTON
State
TX
ZIP
76011
Mailing
2400 CENTENNIAL DRIVE, ARLINGTON, TX 76011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
148
Ownership type
A

3 citations on file for this inspection.

1910.178 P01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s)    At the establishment; in the shipping/receiving area, employees operated the Toyota 5000 pound forklift, model BFGAFGU32, with the left rear tire badly torn and needing replaced or repaired, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2160.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    At the establishment, in the rear bumper line, the power cord powering the Maxess floor fan had the ground prong missing, exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:   At the establishment, a hazard communication program was not developed or maintained when employees were using chemicals such as but not limited to, 3M Finesse-It Polish, exposing employees to the hazard of skin irritations.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

View FLEX-N-GATE, TEXAS, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340482678.